33
Plus 42 - 45 - 50 - 55 - 55S - 55E
11-2000
4. Connect the filler piping to the pump.
5. Re-open P3-P7 (levers on “a”).
6. Immerse the filter with the bottom-drawing valve in the water to be loaded.
The filter must always be below the level of the water to be loaded. The piping must
never be above the pump’s suction point and must never be excessively bent in
the vertical direction.
7. Through the secondary filler BS, pour approximately 15~20 litres of water into the tank: the quantity
must be sufficient to FILL the piping and ACTIVATE the pump to start the recycle.
8. Activate the power take off (PTO) and take it to a rotation speed of at least 500 revs / min.
9. When the pump has started the circulation of the water poured, close tap P3 (lever on “c”) to start
up the filling.
10a.
WITH MEDICINAL MIXTURES OR LIQUID PRODUCTS (WITHOUT MIXER DEVICE)
10a1 Pour the mixture of medicinal envisaged through the main filler (BP), together with the water
used to wash the canister of product and the tools used in the preparation
10a2. Close the main filler (BP) of the tank
10a3. Having completed the filling with water, disengage the power take off (PdP)
10a4. Close the tap (P5) setting the lever in position “c”
10a5. Close the tap (P7) setting the lever in position “c”
10a6. Disconnect the filler piping and replace the stopper on the pump
10a7. Open the tap (P3) of the pump setting the lever in position “a”
10a8. Open the tap (P5) setting the lever in position “a”
10b.
WITH POWDER PRODUCTS: UTILISING THE MIXTURE DEVICE
10b1. Pour the dose of medicinal in powder form foreseen for each loading into the main filler (BP)
of the tank.
10b2. Close the main filler (BP) of the tank
10b3. Open the knob tap of filter (P8)
10b4. Shift the lever of tap (P5) to the ”b” position
10b5. Wait for the filling to be completed
10b6. Close the knob tap of the filter (P8)
10b7. Disengage the power take off (PdP)
10b8. Close taps P5 and P7 (levers on “c”)
10b9. Disconnect the filler piping and replace the stopper on the pump
10b10.Open taps P3 and P5 (levers on “a”)
11. Activate the power take off (PTO) and drive to the area to be treated, keeping a rotation speed
of the power take off (PTO) of least 500 revs/min. for the whole distance.
IN THE AREA OF THE TREATMENT
12. Disengage the power take off (PTO) and rest the machine on the ground.
13.
STOP THE TRACTOR AND REMOVE THE KEY FROM THE CONTROL PANEL
.
14. Make sure that the fan is stopped. Hook the fan to the servo amplifier as indicated at point 8.1.b.
15. Start the tractor, always observing the safety norms.