47
Plus 42 - 45 - 50 - 55 - 55S - 55E
11-2000
2. CAUSE: the 2 drive outlets are out of alignment or are not parallel.
REMEDY
:
Position the 2 drive outlets (PdP) correctly.
E. FAULT: Continuous and abnormal noise level, accompanied by vibrations of fan unit.
1. CAUSE: Broken fan shaft bearings.
REMEDY
:
Refer to the C.I.M.A. service point.
F. FAULT: Intermittent operation of the whole distribution device
1. CAUSE: Faulty sealing of the hydraulic circuit, going from the tank’s (T1) suction piping to the
manual (P10) or electrical (E10) distributor.
REMEDY
:
Carefully inspect all the points at which suction of air can take place, including
as well those at which no liquid seepage is detected. Check the proper tightening of ring
nuts, fittings and clamps. Check the efficiency of the sealers and the integrity of the piping.
Reinstate the efficiency and replace parts that might have been found to be defective.
G. FAULT: Intermittent spraying only on the one side of the distribution device
1. CAUSE: Faulty sealing of the hydraulic circuit going from the manual (P10) or electrical (E10)
distributor to the distribution point involved.
REMEDY
:
As per point F.1.
H. FAULT: No pulverising action delivered: totally or only on the one side of the distribution
device
1. CAUSE: Manual distributor (P10) taps dirty or clogged, or pump suction piping clogged by
hardened product deposits.
REMEDY
:
Clean.
1b.CAUSE: Electrical distributor (E10) taps blocked by incrustations in the closed position.
REMEDY
:
After having lifted the lid off, turn the nut controlling the stroke of the tap.
2b.CAUSE: Fuses of the electrical control panel interrupted when the electrical (E10) distributor’s taps
are closed.
REMEDY
:
Replace the fuses after having manually checked the solenoid valves’
operation.
3b CAUSE: Power cable W1 of the electrical panel wrongly connected with the taps of the electrical
distributor E10 in the closed position.
REMEDY
:
Connect correctly
.
4. CAUSE: Defective electrical connections.
REMEDY:
Refer to the C.I.M.A. service point.
5. CAUSE: Pump defective (only in case total delivery missing).
REMEDY:
Refer to the C.I.M.A. service point.
6. CAUSE: Broken pump belt.
REMEDY:
Replace the belt (See Paragraph 15.1).
THE CAUSES AND REMEDIES FOR THE FAULTS CONCERNING THE DELIVERY OF
THE PULVERISING BY ONE OR MORE DIFFUSERS ARE INDICATED IN THE USER AND
MAINTENANCE MANUAL OF EVERY DISTRIBUTION DEVICE.