39
Plus 42 - 45 - 50 - 55 - 55S - 55E
11-2000
c
. Check the efficiency of the distribution device (head) and the cleaning of the pulverising points
(diffusers), possibly replacing them if found to be damaged.
d.
Clean out the filter cartridge.
e
. Keep the machine in a ventilated place, sheltered from rain or sun: sunrays are the worst enemies
of plastic and rubber parts.
11.4.2 - End of seasonal cycle
•
The operator must:
a
. Take the utmost care in carrying out the operations envisaged at the end of the daily treatments:
the cleaning of the hydraulic circuit must be done at least twice. Check that no product residues
are left in any part of the circuit.
b.
Apply suitable lubrication to all greasing points, then operate the spray atomiser for a few minutes.
c
. Empty the hydraulic circuit completely, with particular attention to the centrifugal pump.
Avoid using anti-freeze solutions.
d
. Check the proper operation of all parts and of the machine structure. In case of faults being
detected, request the intervention of one of our service points.
e
. Keep the machine in a well ventilated place, sheltered from rain, icing and direct sun rays.
The use of detergent products for the cleaning operations is allowed only in the
observance of the regulations in force. For these, the operator must gather the relevant
information from the specifically appointed bodies ruling on this subject.