Страница 1: ...yright decEMBER 2005 By Grizzly Industrial Inc REVISED APRIL 2011 TRTS Warning No portion of this manual may be reproduced in any shape Or form without the written approval of Grizzly Industrial inc For machines mfg since 3 11 BL5685 printed in TAIWAN ...

Страница 2: ...ng grinding tool integrity and the usage of personal protective equipment The manufacturer will not be held liable for injury or property damage from negligence improper training machine modifications or misuse Some dust created by power sanding sawing grinding drilling and other construction activities contains chemicals known to the State of California to cause cancer birth defects or other repr...

Страница 3: ...y 11 Hardware Recognition Chart 12 Site Considerations 13 Floor Load 13 Working Clearances 13 Exhaust Fan 13 Outlet 14 Support Bar 14 Curtains 14 Work Table 15 Filters 16 Ducting 16 Air Filter Indicator 17 SECTION 4 OPERATIONS 18 Filter Indicator 18 SECTION 5 MAINTENANCE 20 Schedule 20 Exhaust Fan and Motor 20 Ducting 20 Air Filter Indicator 20 Interior Booth Walls 20 Exhaust Filters 20 SECTION 6 ...

Страница 4: ...e if the manual version you received matches the manufacture date of your machine For your convenience we post all available man uals and manual updates for free on our website at www grizzly com Any updates to your model of machine will be reflected in these documents as soon as they are complete Manufacture Date of Your Machine Manual Accuracy We stand behind our machines If you have any questio...

Страница 5: ...Shipping Dimensions Type Cardboard Wood Runne Content Machine Weight 754 lbs Length x Width x Height 52 x 27 x 77 in Electrical Power Requirement 230V Single Phase 60 Hz Full Load Current Rating 15A Minimum Circuit Size 20A Switch Magnetic Switch Voltage 220V Cord Length 4 ft Plug Included No Recommended Plug Outlet Type Hardwire Motors Main Type Explosion Proof Horsepower 3 HP Voltage 230V Phase ...

Страница 6: ...2 in Second Stage Filter Thickness 1 3 4 in No Of Third Stage Filters 6 Third Stage Filter Length 15 1 2 in Third Stage Filter Width 15 1 2 in Third Stage Filter Thickness 1 3 4 in Table Info Table Size Length 22 in Table Size Width 51 in Floor To Table Height 51 in Construction Info Frame 16 gauge Steel Base Steel Impeller Aluminum Table 14 gauge Steel Side Wall 18 gauge Steel Frame Filter Pleate...

Страница 7: ... 5 A Spray Booth Frame B Air Filter Indicator C First Stage Filter D Right Curtain E Work Table Leg F Work Table G Support Bar H Left Curtain I Top Curtain J Motor Identification Figure 1 G0533 Identification H I J A B C D E F G ...

Страница 8: ...perate under the influence of drugs or alcohol when tired or when distracted OWNER S MANUAL Read and understand this owner s manual BEFORE using machine Untrained users can be seriously hurt EYE PROTECTION Always wear ANSI approved safety glasses or a face shield when operating or observing machinery to reduce the risk of eye injury or blindness from flying particles Everyday eyeglasses are not ap...

Страница 9: ...ECTION Unless otherwise noted feed work against the rotation of blades or cutters Feeding in the same direction of rotation may pull your hand into the cut FORCING MACHINERY Do not force machine It will do the job safer and better at the rate for which it was designed GUARDS COVERS Guards and covers can protect you from accidental contact with moving parts or flying debris Make sure they are prop ...

Страница 10: ...as been properly ducted away from the work area to the outdoors using 20 gauge spiral welded or 18 gauge rolled galvanized steel ducts lapped in the direction of the air flow and using steel fasteners only RECIRCULATING EXHAUST Do not place the exterior exhaust vent near air conditioning intakes windows or anything else that may recirculate exhaust indoors VOC REDUCTION This spray booth is designe...

Страница 11: ...red to operate on a 230V power supply circuit that has a verified ground and meets the following requirements Nominal Voltage 220V 240V Cycle 60 Hz Phase 1 Phase Circuit Rating 20 Amps For your own safety and protection of property consult a qualified electrician if you are unsure about wiring practices or electrical codes in your area Note The circuit requirements listed in this man ual apply to ...

Страница 12: ...es dur ing the entire setup pro cess This machine and its com ponents are very heavy Get lifting help or use power lifting equipment such as a forklift to move heavy items Your machine was carefully packaged for safe transportation Remove the packaging materials from around your machine and inspect it If you discover the machine is damaged please imme diately call Customer Service at 570 546 9663 ...

Страница 13: ... Work Table 16 Flat Washers 1 4 Support Bar Curtains Work Table 16 Hex Bolts 5 16 18 x 3 4 Curtains 8 Tubing Manometer 2 Tubing Connector Fitting Manometer 1 Plastic Clip Manometer 1 Tap Screw M4 x 12 Manometer 1 Tap Screws M4 x 45 Manometer 2 Red Gauge Oil Manometer 1 Arrow Labels Red and Green 2 F K H G D C M B E I J A L Figure 2 G0533 Inventory N O The following is a description of the main com...

Страница 14: ... 12 Model G0533 Mfg Since 3 11 Hardware Recognition Chart ...

Страница 15: ...m working clearances Unsupervised children and visitors inside your shop could cause serious per sonal injury to themselves Lock all entrances to the shop when you are away and DO NOT allow unsupervised children or visitors in your shop at any time Site Considerations Figure 3 Minimum working clearances top view 52 63 The exhaust fan is very heavy You MUST have assistance when mov ing lifting or m...

Страница 16: ...l the support bar 1 Place the support bar between the lower right and left edges of the spray booth Figure 6 and fasten each side with two 1 4 20 x 5 8 flat head screws two flat washers and two hex nuts Curtains To install the curtains 1 Fasten the hinges Figure 7 of the left cur tain to the front left side of the spray booth each with two 1 4 20 x 5 8 flat head screws flat washers and hex nuts Fi...

Страница 17: ...ver with four 5 16 18 x 3 4 hex bolts as shown in Figure 8 Figure 9 Inserting connector bar Connector Bar Figure 11 Installing table Work Table To install the work table 1 Fasten each of the work table hinges to the spray booth with two 1 4 20 x 5 8 flat head screws flat washers and hex nuts as shown in Figure 11 4 Insert a connector bar into the socket on each curtain brace as shown in Figure 9 F...

Страница 18: ...install the filters 1 Install the six third stage filters into the filter case as shown in Figure 12 Figure 14 First stage filters Figure 13 Second stage filters 3 Install six first stage filters Figure 14 along the outer rails Ducting The G0533 dry spray booth must be vented to the outside of your shop or building using 12 metal spiral wound ducting or 18 gauge rolled galvanized steel ducts in ac...

Страница 19: ...rger pre drilled hole on the side of the booth near the manometer as shown in Figure 16 4 Run tubing from the low pressure side of the manometer to the tubing connector fitting as shown in Figure 16 5 Install tubing into the high pressure side of the manometer and secure it with the plastic clip and an M4 x 12 tap screw as shown in Figure 17 Figure 16 Tubing installed onto spray booth chamber Tubi...

Страница 20: ...ial will not be held liable for accidents caused by lack of training neglect or misuse Filter Indicator NOTICE Never operate the spray booth without all of the air filters installed To fill the air filter indicator manometer 1 Turn the spray booth OFF 2 Disconnect the power 3 Check to make sure the manometer body is level Adjust as needed 4 Rotate the zero adjustment knob counter clockwise Figure ...

Страница 21: ... and mark with the supplied red arrow Figure 20 This is the dirty filter indicator mark When the fluid reaches the red arrow install new filters Note Always make sure the fluid level is at zero before using the spray booth each time Also check the fluid level on a regular basis and re fill as needed Figure 20 Dirty filter mark example Dirty Filter Indicator Mark Figure 19 New filter installation m...

Страница 22: ...icron second stage filter H5839 5 micron third stage filter Immediately remove used filters from the booth Place them in a safe location far away from the booth or place in a water filled metal container to prevent a fire hazard Disposal varies depending on the type of paint being captured Consult local authorities for storage and disposal recommen dations Exhaust Filters Check the air filter indi...

Страница 23: ...in hoses 3 Air filter indicator is not level 1 Check fluid level and add fluid as needed 2 Remove obstructions from hoses 3 Loosen manometer mounting hardware level using sight glass and tighten mounting hardware Spray Booth Operations Symptom Possible Cause Possible Solution Reduced performance with new filters 1 Paint build up on exhaust fan blades or exhaust duct 1 Check exhaust fan blades and ...

Страница 24: ...nce 3 11 Ground Line 2 Line 1 T8 T1 T4 T5 Motor 230V Power Supply Have a qualified electrician install wiring according to NFPA 33 NEC and local regulations Thermostat wires Not Used T2 T3 T6 T7 Not Used G0533 Wiring Diagram ...

Страница 25: ... 11 11 1 11 2 11 3 11 4 11 5 11 6 11 7 11 8 11 9 11 10 11 11 11 12 11 13 11 14 11 15 11 16 11 17 11 18 11 19 11 20 11 21 11 22 11 23 11 24 11 25 11 26 11 27 11 28 12 12 1 12 2 13 14 15 16 17 18 19 20 21 22 23 24 25 26 26 1 26 2 26 3 26 4 27 27 1 27 2 27 3 28 28 1 28 2 28 3 28 4 29 30 31 32 33 34 49 49 1 49 2 Main Parts Breakdown ...

Страница 26: ...6 P0533005 6 RED ARROW 22 PN05 HEX NUT 1 4 20 5 7 P0533005 7 GREEN ARROW 23 PW06 FLAT WASHER 1 4 IN 6 PHTEK46M TAP SCREW M4 X 45 24 PFH04 FLAT HD SCR 1 4 20 X 5 8 7 P0533007 OUTLET 12 25 PFH04 FLAT HD SCR 1 4 20 X 5 8 8 PB03 HEX BOLT 5 16 18 X 1 26 P0533026 WORK TABLE 9 PW07 FLAT WASHER 5 16 26 1 P0533026 1 WORK TABLE LEG 10 PN02 HEX NUT 5 16 18 26 2 PB06 HEX BOLT 5 16 18 X 2 11 P0533011 COVER TOP...

Страница 27: ...L 46 P0532073 ROTATION DIRECTION LABEL 40 PLABEL 15 EAR PROTECTION VL 47 P0533047 IMPELLER HAZARD LABEL 41 P0533041 UNPLUG FILTER CHANGE LABEL 48 P0533048 MACHINE ID LABEL 42 P0532067 NOTICE REGULATIONS LABEL 35 48 40 36 38 42 39 37 41 47 46 43 44 45 Safety labels help reduce the risk of serious injury caused by machine hazards If any label comes off or becomes unreadable the owner of this machine...

Страница 28: ... 26 Model G0533 Mfg Since 3 11 ...

Страница 29: ...r metalworker ____ 0 2 Years ____ 2 8 Years ____ 8 20 Years ____20 Years 6 How many of your machines or tools are Grizzly ____ 0 2 ____ 3 5 ____ 6 9 ____10 7 Do you think your machine represents a good value _____Yes _____No 8 Would you recommend Grizzly Industrial to a friend _____Yes _____No 9 Would you allow us to use your name as a reference for Grizzly customers in your area Note We never use...

Страница 30: ...D LINE FOLD ALONG DOTTED LINE GRIZZLY INDUSTRIAL INC P O BOX 2069 BELLINGHAM WA 98227 2069 Place Stamp Here Name_______________________________ Street_______________________________ City______________State______Zip______ Send a Grizzly Catalog to a friend ...

Страница 31: ......

Страница 32: ...Buy Direct and Save with Grizzly Trusted Proven and a Great Value Since 1983 ORDER 24 HOURS A DAY 1 800 523 4777 Visit Our Website Today For Current Specials ...