Electrical connections should be made by the person with the appropriate permissions. Output
power external devices are located on the controller housing (see the driver) and must be connected
as indicated. Wiring diagram is also in the manual controller.
•
Power supply: 230 V/50Hz.
•
Outputs for external devices : 230V
Caution:
The device must be connected to the supply line run separately secured properly selected circuit
breaker or fuse over-current and residual current circuit breaker. For this line, do not connect any
other electrical appliances!
•
Power burner must be connected via an additional switch of the boiler temperature, for example
STB, which in case of damage control will turn off the burner and will not allow the
temperature of the boiler.
•
Electrical cables must be the entire length of exactly fixed and can not touch the “water coat” of
the boiler, flue pipe and other hot items.
•
Any repairs or installation can be performed only when a voltage is disconnected.
Picture 5 - WIRING DIAGRAMS: