Maintenance photocell. 
If the reading lights on the controller starts to drop it, disconnect the electrical plug burner, remove 
the cover of the burner, remove the Photo element of the sleeve and clean the surface with a dry soft 
cloth.  This  action  is  performed  at  least  once  during  the  1-2  heating  season,  or  more  frequently  if 
necessary. 
Cleaning the air duct burner. 
To do this: 
• Remove the burner or open the door of the burner. 
• Remove the heat shield and sealing of the furnace grate. 
• Remove and clean the cast iron grate blowing holes in the surface 
• Remove ashes from the air duct under the grate and clean the vents holes on the back burner 
chamber around the internal screw (Stoker). 
• Reinstall the grate, burner plate and seal. 
Cleaning the burner must be made with a disconnected electrical connector from the burner at least 
1-2 times during the heating season, or more frequently if necessary. 
 
Cleaning the fan. 
Before each heating season, remove the burner and fan with a brush or compressed air to clear the 
shoulders of pollution. 
 
 
Replacing the igniter. 
Electric  igniter  is  used  to  fire  the  pellet  is  a  consumable  item,  and  its  lifetime  depends  on  the 
number ignitions, their duration, power fan with ignition or correct adjustment. The life expectancy 
is one to three heating seasons. If damaged replace it. 
To do this: 
• Disconnect the electrical connector and disassemble the burner housing. 
• Disconnect heater wires from the electrical connector (see wiring diagram) 
• disassemble the internal screw drive and the back cover of the burner. 
• In the auger tube is mounted ignition (heat). Is screwed to the side of the set crew, which unscrew 
and remove the lighter. 
• Install a new nut and tighten the screw. 
• Connect the wires to the electrical connector lighter burner. 
• Mount the enclosure and drive. 
 
Elements of performance. 
Torch  building  elements  such  as  ignition,  cast  iron  grate,  burner  heat  shield,  gasket,  sealing  cords 
are consumable and they have only guarantee the boot. They should be replaced as wear every 1-3 
heating seasons. 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание MOC 20

Страница 1: ...reate a danger for end user Table of Contents 1 Admission 2 Purpose burners 3 Design and technical specification 4 Safety 5 Burner s installation and requirements 6 Operation 7 Maintenance 8 Problems...

Страница 2: ...erformed in accordance with applicable standards and regulations Required fuel Wood pellet 6 8mm cross section length 5 30mm ash content max 2 The maximum moisture content of pellets should not exceed...

Страница 3: ...let feeding tube 3 Electrical connector Plug 4 Internal burner feeder Stoker 5 Furnace heat shield 6 Cast iron grill 7 Furnace body 8 Electric igniter 9 The air fan 10 Burner s steel cover Picture 2 B...

Страница 4: ...er are delivered in one box nr1 and feeding screw is in separate box nr 2 Picture 3 Transportation package 4 Safety Safety Tips 1 Starting the burner and its operation can be effected only by adults a...

Страница 5: ...Pine larch wood spruce wood cork rubber base C3 easy burning asphalt celluloid polyurethane polystyrene plastic PVC 5 Burner s installation and requirements Tips for Installer During the installation...

Страница 6: ...the burner mounting hole in existing door or additional mounting plate Opening dimensions in Picture 2 dimensions of the burner 2 Seal the space between the burner and door gasket with non combustibl...

Страница 7: ...roperly selected circuit breaker or fuse over current and residual current circuit breaker For this line do not connect any other electrical appliances Power burner must be connected via an additional...

Страница 8: ...8 12 03 12 Electrical wiring diagrams of other external devices are in manual book of each controller...

Страница 9: ...resistant materials and be warmed throughout Allowed brick chimneys provided a good thermal insulation of the chimney Section of the flue from the boiler to the chimney flue should have called a sligh...

Страница 10: ...space led to the roof of at least 1 5 m flue should be made of noncombustible material 6 Operation Start up burner Preparation for start up should include a general overview of the technical condition...

Страница 11: ...o observe the changes The fine adjustment is recommended for analysis of exhaust To adjust the power of the burner set working hours and time off work enough to feed pellet was delivered within 1 hour...

Страница 12: ...the fan Before each heating season remove the burner and fan with a brush or compressed air to clear the shoulders of pollution Replacing the igniter Electric igniter is used to fire the pellet is a...

Страница 13: ...atically No fuel Fill up the fuel In the fuel Silo Improper adjustment of start pellet amount time lighting power fan Readjust Dirty burner Clean the combustion chamber of the burner Defective igniter...

Страница 14: ...ectrical connector 8 Back part of the burner 9 Sealing of the stoker tube 10 Sealing the back cover 11 Igniter 12 Internal burner s feeder stoker 13 Feeding tube pipe 14 Back Cover 15 Gear motor with...

Страница 15: ...ling cords gaskets thermal plate burner grate and burner ignition Damage to mechanical thermal chemical caused by improper operation or failure to maintain control of the boiler Damage caused by elect...

Отзывы: