12
12/03/12
Maintenance photocell.
If the reading lights on the controller starts to drop it, disconnect the electrical plug burner, remove
the cover of the burner, remove the Photo element of the sleeve and clean the surface with a dry soft
cloth. This action is performed at least once during the 1-2 heating season, or more frequently if
necessary.
Cleaning the air duct burner.
To do this:
• Remove the burner or open the door of the burner.
• Remove the heat shield and sealing of the furnace grate.
• Remove and clean the cast iron grate blowing holes in the surface
• Remove ashes from the air duct under the grate and clean the vents holes on the back burner
chamber around the internal screw (Stoker).
• Reinstall the grate, burner plate and seal.
Cleaning the burner must be made with a disconnected electrical connector from the burner at least
1-2 times during the heating season, or more frequently if necessary.
Cleaning the fan.
Before each heating season, remove the burner and fan with a brush or compressed air to clear the
shoulders of pollution.
Replacing the igniter.
Electric igniter is used to fire the pellet is a consumable item, and its lifetime depends on the
number ignitions, their duration, power fan with ignition or correct adjustment. The life expectancy
is one to three heating seasons. If damaged replace it.
To do this:
• Disconnect the electrical connector and disassemble the burner housing.
• Disconnect heater wires from the electrical connector (see wiring diagram)
• disassemble the internal screw drive and the back cover of the burner.
• In the auger tube is mounted ignition (heat). Is screwed to the side of the set crew, which unscrew
and remove the lighter.
• Install a new nut and tighten the screw.
• Connect the wires to the electrical connector lighter burner.
• Mount the enclosure and drive.
Elements of performance.
Torch building elements such as ignition, cast iron grate, burner heat shield, gasket, sealing cords
are consumable and they have only guarantee the boot. They should be replaced as wear every 1-3
heating seasons.