4
12/03/12
U
n
it
:
Type:
M
O
C
2
0
M
O
C
4
0
M
O
C
6
0
Nominal power output (> 17,5 MJ/kg)
kW
25
40
60
Power modulation range (min.-max.)
kW
8-25
15-40
20-60
Recomended chimney’s under pressure
Pa
10-20
Min. diameter of the chimney
mm
140
160
180
Min. height of the chimney
m
8
8
8
Burner’s efficiency
%
> 92 %
The stream of fuel for maximum power
kg/h
5,59
8,94
13,42
The stream of fuel for minimum power
kg/h
1,69
3,35
4,47
Fuel
Pellet 6-8 mm
Power consumption
kW
0,442
Weight
kg
--
--
--
Delivery – Burner and controller are delivered in one box (nr1) and feeding screw is in separate box
(nr 2)
Picture 3 – Transportation package.
4. Safety.
Safety Tips:
1.
Starting the burner and its operation can be effected only by adults after having regard to the
technical and user documentation.
2.
Near the operating unit should not accommodate children without adult supervision
3.
Before starting it is necessary to validate the burner to the boiler installation against
electrical and mechanical.
4.
To ignite the fuel does not use solvents, gasoline, etc.
5.
During the fire the fuel is not allowed to look inside the chamber because it may explode.
6.
The ash must be removed for non-combustible container with a tight lid.