Cichewicz MOC 20 Скачать руководство пользователя страница 15

15 

 

12/03/12 

 
 
10. Warranty card. 
 

Warranty conditions: 

 

1.

 

The manufacturer provides 24 months warranty on the proper operation of the burner MOC 
but not longer than 36 months from the date of its sales agent. 

2.

 

During the warranty period end user is entitled to free repair service problems arising from 
the fault of the manufacturer  within 14 days  from the date of delivery of equipment to the 
place of. 

3.

 

Repairs during the warranty period at the customer is charged. Are free of charge, while the 
parts that are replaced under warranty. 

4.

 

The warranty does not cover: 

-    Use  elements  :  sealing  cords,  gaskets,  thermal  plate  burner  grate  and  burner  ignition. 
-    Damage  to  mechanical,  thermal,  chemical,  caused  by  improper  operation,  or  failure  to 
maintain 

control 

of 

the 

boiler. 

Damage 

caused 

by 

electrical 

surges, 

flooding 

the 

unit. 

-  Damage  caused  by  improper  installation  or  improper  selection  of  equipment. 
-    Maintenance and control of the burner. 
 5. The complaint should contain the minutes of the start-up, invoice of purchase, description of 
damage and the applicant. 

 
 
 
 
 
 

 
Changes made unlawful in the mechanical or electrical burner design will be treated 
as a violation of the guarantee, which will result in immediate termination there of. 
 

 
 
 
 
 
 
 
 
 
 
 

 
The manufacturer reserves the right to change some of the technical data 
contained in   this manual due to the continuous improvement of products. 
 

 

Содержание MOC 20

Страница 1: ...reate a danger for end user Table of Contents 1 Admission 2 Purpose burners 3 Design and technical specification 4 Safety 5 Burner s installation and requirements 6 Operation 7 Maintenance 8 Problems...

Страница 2: ...erformed in accordance with applicable standards and regulations Required fuel Wood pellet 6 8mm cross section length 5 30mm ash content max 2 The maximum moisture content of pellets should not exceed...

Страница 3: ...let feeding tube 3 Electrical connector Plug 4 Internal burner feeder Stoker 5 Furnace heat shield 6 Cast iron grill 7 Furnace body 8 Electric igniter 9 The air fan 10 Burner s steel cover Picture 2 B...

Страница 4: ...er are delivered in one box nr1 and feeding screw is in separate box nr 2 Picture 3 Transportation package 4 Safety Safety Tips 1 Starting the burner and its operation can be effected only by adults a...

Страница 5: ...Pine larch wood spruce wood cork rubber base C3 easy burning asphalt celluloid polyurethane polystyrene plastic PVC 5 Burner s installation and requirements Tips for Installer During the installation...

Страница 6: ...the burner mounting hole in existing door or additional mounting plate Opening dimensions in Picture 2 dimensions of the burner 2 Seal the space between the burner and door gasket with non combustibl...

Страница 7: ...roperly selected circuit breaker or fuse over current and residual current circuit breaker For this line do not connect any other electrical appliances Power burner must be connected via an additional...

Страница 8: ...8 12 03 12 Electrical wiring diagrams of other external devices are in manual book of each controller...

Страница 9: ...resistant materials and be warmed throughout Allowed brick chimneys provided a good thermal insulation of the chimney Section of the flue from the boiler to the chimney flue should have called a sligh...

Страница 10: ...space led to the roof of at least 1 5 m flue should be made of noncombustible material 6 Operation Start up burner Preparation for start up should include a general overview of the technical condition...

Страница 11: ...o observe the changes The fine adjustment is recommended for analysis of exhaust To adjust the power of the burner set working hours and time off work enough to feed pellet was delivered within 1 hour...

Страница 12: ...the fan Before each heating season remove the burner and fan with a brush or compressed air to clear the shoulders of pollution Replacing the igniter Electric igniter is used to fire the pellet is a...

Страница 13: ...atically No fuel Fill up the fuel In the fuel Silo Improper adjustment of start pellet amount time lighting power fan Readjust Dirty burner Clean the combustion chamber of the burner Defective igniter...

Страница 14: ...ectrical connector 8 Back part of the burner 9 Sealing of the stoker tube 10 Sealing the back cover 11 Igniter 12 Internal burner s feeder stoker 13 Feeding tube pipe 14 Back Cover 15 Gear motor with...

Страница 15: ...ling cords gaskets thermal plate burner grate and burner ignition Damage to mechanical thermal chemical caused by improper operation or failure to maintain control of the boiler Damage caused by elect...

Отзывы: