Cichewicz MOC 20 Скачать руководство пользователя страница 6

 

12/03/12 

- Boiler, to which the burner is mounted should have sufficient size combustion chamber allowing 
the free distribution of flame from the burner. 
-  Minimum  distance  of  the  burner  from  the  rear  wall  of  the  combustion  chamber  are  given  in  Fig 
dimensions as dimension "A". On the sides of the burner must be provided at intervals of at least 5 
cm., And the burner 15-20cm. The distances from the burner boiler walls can vary in the boilers of 
various designs 
- Feeder should be mounted external to the tank at an angle of about 45% relative to the ground. 
-  Feeder  hose  connecting  an  external  burner  should  provide  the  gravitational  fall  of  fuel  to  the 
burner. 
 
Installation of the burner: 

1.

 

Follow  the  burner  mounting  hole  in  existing  door  or  additional  mounting  plate.  Opening 
dimensions in Picture 2 - dimensions of the burner. 

2.

 

Seal  the  space  between  the  burner  and  door  gasket  with  non-combustible  material  (high-
temperature insulating boards, mineral fiber gaskets, etc.). 

3.

 

Remove the burner housing (cover). 

4.

 

Mount the burner on the door. Tighten it with screws. Bolt holes are located on the sides of 
the mounting flange of the burner. 

5.

 

Connect the burner to the controller and mount the temperature sensor of the measuring tube 
boiler in the boiler. 

Attach the main feeder outside the fuel tank and connect it to the controller. 
Note the notch on the part of the feeding tube which is mounted in the tank and set it so that 
pellets fell into this hole. 
Install flexible tube connecting the burner with a feeder outside and secure it with straps. 
 

Picture nr 4 - connection 

 

 
 
 
 
Ectrical connection: 

Содержание MOC 20

Страница 1: ...reate a danger for end user Table of Contents 1 Admission 2 Purpose burners 3 Design and technical specification 4 Safety 5 Burner s installation and requirements 6 Operation 7 Maintenance 8 Problems...

Страница 2: ...erformed in accordance with applicable standards and regulations Required fuel Wood pellet 6 8mm cross section length 5 30mm ash content max 2 The maximum moisture content of pellets should not exceed...

Страница 3: ...let feeding tube 3 Electrical connector Plug 4 Internal burner feeder Stoker 5 Furnace heat shield 6 Cast iron grill 7 Furnace body 8 Electric igniter 9 The air fan 10 Burner s steel cover Picture 2 B...

Страница 4: ...er are delivered in one box nr1 and feeding screw is in separate box nr 2 Picture 3 Transportation package 4 Safety Safety Tips 1 Starting the burner and its operation can be effected only by adults a...

Страница 5: ...Pine larch wood spruce wood cork rubber base C3 easy burning asphalt celluloid polyurethane polystyrene plastic PVC 5 Burner s installation and requirements Tips for Installer During the installation...

Страница 6: ...the burner mounting hole in existing door or additional mounting plate Opening dimensions in Picture 2 dimensions of the burner 2 Seal the space between the burner and door gasket with non combustibl...

Страница 7: ...roperly selected circuit breaker or fuse over current and residual current circuit breaker For this line do not connect any other electrical appliances Power burner must be connected via an additional...

Страница 8: ...8 12 03 12 Electrical wiring diagrams of other external devices are in manual book of each controller...

Страница 9: ...resistant materials and be warmed throughout Allowed brick chimneys provided a good thermal insulation of the chimney Section of the flue from the boiler to the chimney flue should have called a sligh...

Страница 10: ...space led to the roof of at least 1 5 m flue should be made of noncombustible material 6 Operation Start up burner Preparation for start up should include a general overview of the technical condition...

Страница 11: ...o observe the changes The fine adjustment is recommended for analysis of exhaust To adjust the power of the burner set working hours and time off work enough to feed pellet was delivered within 1 hour...

Страница 12: ...the fan Before each heating season remove the burner and fan with a brush or compressed air to clear the shoulders of pollution Replacing the igniter Electric igniter is used to fire the pellet is a...

Страница 13: ...atically No fuel Fill up the fuel In the fuel Silo Improper adjustment of start pellet amount time lighting power fan Readjust Dirty burner Clean the combustion chamber of the burner Defective igniter...

Страница 14: ...ectrical connector 8 Back part of the burner 9 Sealing of the stoker tube 10 Sealing the back cover 11 Igniter 12 Internal burner s feeder stoker 13 Feeding tube pipe 14 Back Cover 15 Gear motor with...

Страница 15: ...ling cords gaskets thermal plate burner grate and burner ignition Damage to mechanical thermal chemical caused by improper operation or failure to maintain control of the boiler Damage caused by elect...

Отзывы: