- Boiler, to which the burner is mounted should have sufficient size combustion chamber allowing
the free distribution of flame from the burner.
- Minimum distance of the burner from the rear wall of the combustion chamber are given in Fig
dimensions as dimension "A". On the sides of the burner must be provided at intervals of at least 5
cm., And the burner 15-20cm. The distances from the burner boiler walls can vary in the boilers of
various designs
- Feeder should be mounted external to the tank at an angle of about 45% relative to the ground.
- Feeder hose connecting an external burner should provide the gravitational fall of fuel to the
burner.
Installation of the burner:
1.
Follow the burner mounting hole in existing door or additional mounting plate. Opening
dimensions in Picture 2 - dimensions of the burner.
2.
Seal the space between the burner and door gasket with non-combustible material (high-
temperature insulating boards, mineral fiber gaskets, etc.).
3.
Remove the burner housing (cover).
4.
Mount the burner on the door. Tighten it with screws. Bolt holes are located on the sides of
the mounting flange of the burner.
5.
Connect the burner to the controller and mount the temperature sensor of the measuring tube
boiler in the boiler.
Attach the main feeder outside the fuel tank and connect it to the controller.
Note the notch on the part of the feeding tube which is mounted in the tank and set it so that
pellets fell into this hole.
Install flexible tube connecting the burner with a feeder outside and secure it with straps.
Picture nr 4 - connection
Ectrical connection: