Starting dose
For a normal ignition is needed about 0,20-0,3 L pellets. Time must be chosen so the feeder at the 
start that the amount of pellet was appropriate. 
Firing time. 
This  is  the  time  after  which  the  controller  if  you  do  not  see  the  flame  on  the  burner  complete  the 
process of firing, ie, off lighter. Please set it as short as possible because it increases the life of the 
heater. As a rule, is 6-10 min. 
Number of attempts to ignite. 
Number of attempts to ignite after which it will not ignite if the driver will go into alarm. Standard 
setting 2 sample. Do not set more because too much fuel to the burner may cause interference to the 
device. 
Photocell. 
The task of the photocell (photocell) is to show the initiation of the ignition burner as well as being 
a source of information for the controller that the burner is extinguished. 
Photocell settings depending on the type of controller are: 
- The threshold of firing, ie, the reading lights above which the regulator considers that the ignition, 
- The type of photocell, 
- Its sensitivity. 
The amount of fuel and power fan 
Time  of  the  feeder  as  well  as  fan  power  should  be  chosen  so  that  the  flame  was 
stable, and its colour should be bright red. White flame indicates too much aeration chamber of the 
burner, a dark red to a lack of air. 
Each time after changing settings in the controller must wait a few minutes to observe the changes. 
The 

fine 

adjustment 

is 

recommended 

for 

analysis 

of 

exhaust. 

To adjust the power of the burner, set working hours and time off work enough to feed pellet was 
delivered within 1 hour to the burner. 
From  1  kg  of  pellets  can  be  obtained  within  4-5kW.  So  for  example,  25  kW  power  must  give  at 
least 5 kg of fuel during 1h. Regulators are adjustable by the minimum and maximum employment 
as well as modulated. 
Startup and shut down the burner. 
Starting  the  burner  will  start  automatically  when  you  press    START  button  on  the  controller.  
Combustion  will  take  place  automatically,  ie,  he  will  seek  to  maintain  a  preset  temperature  is 
exceeded  after  a  self-extinguish.  When  the  boiler  temperature  drops  below  the  histeresis  value  set 
will restart the burner. 
To switch off, go to the stop function on or off the controller. 
 
The detailed methods of setting and description of the parameters refer to the manual controller (RK 
2006LP or Ecomax 800P). 
 

7

 

Maintenance. 

 
Cleaning the outside cover. 
Clean the exterior cover of the burner with a slightly damp cloth and detergent agents. 
 
Ash removal: 
Empty  the  ash,  as  few  or  several  days  depending  on  the  load  at  which  the  boiler  is  working,  ash 
content in the fuel, the size of the ash in the boiler. 
If the burner creates a gangrene (“ash stone”) should be removed because it may hinder the lighting 
and proper combustion. With poor quality pellets this should be checked every 1-3 days. 
With good quality pellets on the burner should not create a gangrene (lumps of molten ash) and then 
control and cleaning can be done every few weeks. 
 

Содержание MOC 20

Страница 1: ...reate a danger for end user Table of Contents 1 Admission 2 Purpose burners 3 Design and technical specification 4 Safety 5 Burner s installation and requirements 6 Operation 7 Maintenance 8 Problems...

Страница 2: ...erformed in accordance with applicable standards and regulations Required fuel Wood pellet 6 8mm cross section length 5 30mm ash content max 2 The maximum moisture content of pellets should not exceed...

Страница 3: ...let feeding tube 3 Electrical connector Plug 4 Internal burner feeder Stoker 5 Furnace heat shield 6 Cast iron grill 7 Furnace body 8 Electric igniter 9 The air fan 10 Burner s steel cover Picture 2 B...

Страница 4: ...er are delivered in one box nr1 and feeding screw is in separate box nr 2 Picture 3 Transportation package 4 Safety Safety Tips 1 Starting the burner and its operation can be effected only by adults a...

Страница 5: ...Pine larch wood spruce wood cork rubber base C3 easy burning asphalt celluloid polyurethane polystyrene plastic PVC 5 Burner s installation and requirements Tips for Installer During the installation...

Страница 6: ...the burner mounting hole in existing door or additional mounting plate Opening dimensions in Picture 2 dimensions of the burner 2 Seal the space between the burner and door gasket with non combustibl...

Страница 7: ...roperly selected circuit breaker or fuse over current and residual current circuit breaker For this line do not connect any other electrical appliances Power burner must be connected via an additional...

Страница 8: ...8 12 03 12 Electrical wiring diagrams of other external devices are in manual book of each controller...

Страница 9: ...resistant materials and be warmed throughout Allowed brick chimneys provided a good thermal insulation of the chimney Section of the flue from the boiler to the chimney flue should have called a sligh...

Страница 10: ...space led to the roof of at least 1 5 m flue should be made of noncombustible material 6 Operation Start up burner Preparation for start up should include a general overview of the technical condition...

Страница 11: ...o observe the changes The fine adjustment is recommended for analysis of exhaust To adjust the power of the burner set working hours and time off work enough to feed pellet was delivered within 1 hour...

Страница 12: ...the fan Before each heating season remove the burner and fan with a brush or compressed air to clear the shoulders of pollution Replacing the igniter Electric igniter is used to fire the pellet is a...

Страница 13: ...atically No fuel Fill up the fuel In the fuel Silo Improper adjustment of start pellet amount time lighting power fan Readjust Dirty burner Clean the combustion chamber of the burner Defective igniter...