Remote Operation
4-37
minimum value of static load.
Query Syntax:
[ADVance:]CURRent:SWEep:FALL?[<space><MAX | MIN>]
Return Parameters:<NR2>, [Unit =
A/μs]
Query Example:
CURR:SWE:FALL?
CURR:SWE:FALL? MAX
CURR:SWE:FALL? MIN
[ADVance:]IMPedance:STATic:CL
Type:
Channel-Specific
Description:
Set the equivalent parallel load capacitance for constant impedance
mode.
Setting Syntax:
[ADVance:]IMPedance:STATic:CL<space><NRf+>[suffix]
Setting Parameters:<NRf+>, 30μF ~ 50,000μF, Resolution = 1uF, Unit = Farad
Setting Example: IMP:STAT:CL 0.02
Set capacitance = 20mF.
IMP:STAT:CL 100μF
Set capacitance = 100μF.
IMP:STAT:CL MAX
Set capacitance = maximum value.
IMP:STAT:CL MIN
Set capacitance = minimum value.
Query Syntax:
[ADVance:]IMPedance:STATic:CL?[<space><MAX | MIN>]
Return Parameters:<NR2>, [Unit = Farad]
Query Example:
IMP:STAT:CL?
IMP:STAT:CL? MAX
IMP:STAT:CL? MIN
[ADVance:]IMPedance:STATic:LS
Type:
Channel-Specific
Description:
Set the equivalent series inductance for constant impedance mode.
Setting Syntax:
[ADVance:]IMPedance:STATic:LS<space><NRf+>[suffix]
Setting Parameters:<NRf+>, 0 ~ 20.0μH, Resolution = 0.1μH, Unit = Henry
Setting Example: IMP:STAT:LS 0.00002
Set inductance = 20μH.
IMP:STAT:LS 1μH
Set inductance = 1μH.
IMP:STAT:LS MAX
Set inductance = maximum value.
IMP:STAT:LS MIN
Set inductance = minimum value.
Query Syntax:
[ADVance:]IMPedance:STATic:LS?[<space><MAX | MIN>]
Return Parameters:<NR2>, [Unit = Henry]
Query Example:
IMP:STAT:LS?
IMP:STAT:LS? MAX
IMP:STAT:LS? MIN
[ADVance:]IMPedance:STATic:RS
Type:
Channel-Specific
Description:
Set the equivalent series resistance for constant impedance mode.
Setting Syntax:
[ADVance:]IMPedance:STATic:RS<space><NRf+>[suffix]
Setting Parameters:<NRf+>, 0.03Ω ~ 20.00Ω, Resolution = 0.01Ω, Unit = Ohm
Setting Example: IMP:STAT:RS 20
Set resistance = 20Ω.
IMP:STAT:RS 10 OHM
Set resistance = 10Ω.
IMP:STAT:RS MAX
Set resistance = maximum value.
IMP:STAT:RS MIN
Set resistance = minimum value.
Query Syntax:
[ADVance:]IMPedance:STATic:RS?[<space><MAX | MIN>]
Return Parameters:<NR2>, [Unit = OHM]
Query Example:
IMP:STAT:RS?
IMP:STAT:RS? MAX
IMP:STAT:RS? MIN
Содержание 63200A Series
Страница 1: ...High Power Electronic Load 63200A Series Operation Programming Manual ...
Страница 2: ...High Power Electronic Load 63200A Series Operation Programming Manual Version 1 0 March 2015 ...
Страница 7: ...vi ...
Страница 11: ......
Страница 15: ......
Страница 22: ...Overview 1 7 Figure 1 3 Dimension of 63200A with Protection Cover ...
Страница 23: ......
Страница 31: ......
Страница 127: ......