Manual Operation
4. Press
“
EXIT
” to return to MAIN PAGE.
3.3.4.2 READING
AVERAGE
TIMES
The voltage and current readings displayed on the MAIN PAGE is five and half digits, and
the option READING AVERAGE TIMES = is able to set the average times for voltage and
current readings. The bigger the average times are set, the slower the voltage and current are
updated. The default setting is 1 as Figure 3-55 shows.
[ D I S P L A Y S E L E C T I O N ]
D I S P L A Y S E L E C T I ON
= N O N E
R
E A
D
I
N
G A
V
E
R
A
G
E T I ME S = 1
Figure 3-55
READING AVERAGE TIMES can be set to 1, 2, 4 and 8.
NOTICE
1. The reading is averaged by ROLLING; therefore, when the actual output is changed
dramatically and the average times are larger than 1, the displayed reading will reach for
the actual output based on the average times gradually.
2. The panel reading is updated in the rate of 200mS.
3.3.5 PROTECTION
Chroma 62000P Series DC Power Supplies have complete protection functions divided in two
classes. The first type protection includes over voltage, over current, over power and
FOLDBACK; while the second type protection includes over temperature, fan failure and
over/under input voltage. The first class protection trigger point is set by user as described
below, while the second class protection is auto detected by the system hardware protection
circuit.