Programmable DC Power Supply 62000P Series Operating & Programming Manual
[ O U T P U T S E T U P ]
V L I M I T : M A X = 8 0 . 0 0 V M I N =
0 0 0 . 0 0 V
I L I M I T : M A X = 1 5 . 0 0 A M I N =
0 0 0 . 0 0 A
V S L E W R A T E = 1 . 0 0 ( V / m S )
I S L E
W R A T E = 1 . 0 0 ( A / m S )
T T L V A L U E =
0 ( D E C )
<
B I N
A
R
Y =
0 0 0 0 0 0 0 0 >
Figure 3-16
Following introduces the options of OUTPUT SETTING.
3.3.2.1 VOLTAGE LIMIT SETTING
1. Use
“
”, “
” keys to move the cursor to the column to be set.
[ O U T P U T S E T U P ]
V L I M I T :
M A X = 8 0 . 0 0 V M I N =
0 0 0 . 0 0 V
I L I M I T :
M A X = 1 5 . 0 0 A M I N =
0 0 0 . 0 0 A
V S L E W R A T E = 1 . 0 0 ( V / m S )
I S L E
W R A T E = 1 . 0 0 ( A / m S )
T T L V A L
U E =
0 ( D E C )
<
B I N
A
R
Y = 0 0 0 0 0 0 0 0 >
Figure 3-17
2. Use the numeric (
0
~
9
) keys or “Rotary” (
) knob to set the value.
Take example by 62012P-80-60, the output voltage range is 0~80V and use this option
can narrow down its range by setting MIN and MAX.
When “
VOLTAGE
” is pressed to set the output voltage, the DC Power Supply allows setting
the voltage within the range of [MIN value
≤
user-defined value
≤
MAX value]. If the
setting exceeds the range, the BUZZER will beep (if BUZZER is set to ON) and the
main screen will prompt a warning message automatically as shown below. In the
meantime, the system will modify the voltage limit of MIN or MAX automatically.
3-12