Installation
2.5.3
Reverse Connection of Remote Sensing Wire Polarity
The polarity of remote sensing wire must be connected correctly, that is the “
+
” terminal is
connected to the “
+
” of output terminal or to the connecting wire of the terminal, while the
“
-
” terminal is connected to the “
-
” of output terminal or to the connecting wire of the
terminal. If the polarity is connected reversely, the output will drop to 0V and prompt an
error message “
RMT FAULT
” as Figure 2-7 shows.
V _ S E T = 8 0 . 0 0 V I _ S E T = 1 5 . 0 0 A
O F F
0 0 . 0 0 V
0 0 . 0 0 A
0 . 0
W
S E N S E F A U L T
Figure 2-7
NOTICE
The DC Power Supply does not burn down due to reverse connection of polarity. Do the
following step to reset it:
1. First power it off.
2. Connect the remote sensing wire properly.
3. Restart the DC Power Supply.
2.5.4
Rack Mounting Kit & Handle Installation
Remove the sliver inlay from the plastic side frame and use M4X15 flat head screws to secure
the rack mounting kit to the plastic side frame. If a handle is required for installation, use
M4X9 flat head screws to secure it to the rack mounting kit as shown below.
Figure 2-8
2-7