Remote Operation
5-25
Syntax:
PROGram:PULL <ARG>
Parameter:
<ARG>: LOW | HIGH
Example:
PROGram:PULL LOW
Query Syntax:
PROGram:PULL?
Return Parameter:
LOW | HIGH
Query Example:
PROGram:PULL?
Return Example:
LOW
8.
PROGram:SEQuence:SELected
Description:
Sets the execution sequence of a program in List mode.
Syntax:
PROGram:SEQuence:SELected <NR1>
Parameter:
1 to the sequence no. of present program.
Example:
PROG:SEQ:SEL 3
Query Syntax:
PROGram:SEQuence:SELected? [{MAX/MIN}]
Return Parameter:
<NR1>
Query Example:
PROG:SEQ:SEL?
Return Example:
3
9.
PROGram:SEQuence:TYPE
Description:
Sets the action type of a sequence in List mode.
Syntax:
PROGram:SEQuence:TYPE <Arg>
Parameter:
<Arg> AUTO | MANUAL | TRI | SKIP
Example:
PROG:SEQ:TYPE AUTO
Query Syntax:
PROG:SEQ:TYPE?
Return Parameter:
AUTO | MANUAL | EXT.TRIGGER | SKIP
Query Example:
PROG:SEQ:TYPE?
Return Example:
AUTO
10. PROGram:SEQuence:VOLTage
Description:
Sets the sequence for voltage output in List mode.
Syntax:
PROGram:SEQuence:VOLTage <NRf+>
Parameter:
<NRf+>
Example:
PROG:SEQ:VOLT 40.5
Query Syntax:
PROG:SEQ:VOLT? [{MAX/MIN}]
Return Parameter:
<NRf+>
Query Example:
PROG:SEQ:VOLT?
Return Example:
4.01
11. PROGram:SEQuence:VOLTage:SLEW
Description:
Sets the sequence of voltage slew rate for output in List mode.
Syntax:
PROGram:SEQuence:VOLTage:SLEW <NRf+>
Parameter:
<NRf+>
Example:
PROG:SEQ:VOLT:SLEW 1
Query Syntax:
PROG:SEQ:VOLT:SLEW? [{MAX/MIN}]
Return Parameter:
<NRf+>
Query Example:
PROG:SEQ:VOLT:SLEW?
Return Example:
1.01
12. PROGram:SEQuence:CURRent
Description:
Sets the sequence for Source current output in List mode.
Syntax:
PROGram:SEQuence:CURRent <NRf+>
Parameter:
<NRf+>
Example:
PROG:SEQ:CURR 45
Query Syntax:
PROG:SEQ:CURR? [{MAX/MIN}]
Содержание 62000D Series
Страница 1: ......
Страница 2: ...Get more information by downloading Chroma ATE Solutions APP ...
Страница 8: ...vi ...
Страница 9: ...vii ...
Страница 10: ...viii ...
Страница 14: ......
Страница 18: ......
Страница 35: ...Overview 1 17 Figure 1 6 Dimension of 62000D 600 1200 1800 Models ...
Страница 36: ......
Страница 52: ......
Страница 54: ...Programmable Bidirectional DC Power Supply 62000D Series Operating and Programming Manual 3 2 Figure 3 2 ...
Страница 63: ...Manual Operation 3 11 Figure 3 13 Figure 3 14 ...
Страница 109: ...Manual Operation 3 57 _EXT ON SIGNAL EXT ON DISABLE EXT ON ENABLE Output Output Figure 3 85 ...
Страница 110: ......
Страница 117: ...Program Sequence 4 7 Figure 4 8 Figure 4 9 ...