Programmable Bidirectional DC Power Supply 62000D Series
Operating and Programming Manual
5-18
SOURce:VOLTage:LIMIT:LOW <NRf+>[suffix]
Parameter:
Refer to individual spec for valid numeric range.
Example:
SOUR:VOLT:LIMIT:HIGH 60.0 It sets the output voltage range
to 60V maximum.
SOUR:VOLT:LIMIT:LOW 20.0 It sets the output voltage range
to 20V minimum.
Query Syntax:
SOUR:VOLT:LIMIT:HIGH? [{MAX/MIN}]
SOUR:VOLT:LIMIT:LOW? [{MAX/MIN}]
Return Parameter:
<NRf+> [Unit=Volt]
Query Example:
SOUR:VOLT:LIMIT:HIGH?
It returns the voltage high limit.
SOUR:VOLT:LIMIT:HIGH? MAX It returns the max. voltage can
be set.
Return Example:
8.01
3.
SOURce:VOLTage:PROTect:HIGH
Description:
Sets the voltage range for over voltage protection.
Syntax:
SOURce:VOLTage:PROTect:HIGH <NRf+>[suffix]
Parameter:
Refer to individual spec for valid numeric range.
Example:
SOUR:VOLT:PROT:HIGH 60.0 It sets the high limit to 60V for
voltage output protection.
Query Syntax:
SOUR:VOLT:PROT:HIGH? [{MAX/MIN}]
Return Parameter:
<NRf+> [Unit=Volt]
Query Example:
SOUR:VOLT:PROT:HIGH?
It returns the high limit of
voltage protection.
SOUR:VOLT:PROT:HIGH? MAX
It returns the max. over
voltage protection.
Return Example:
8.01
4.
SOURce:VOLTage:SLEW
Description:
Sets the rising or falling slew rate (volt/ms) of output voltage.
Syntax:
SOURce:VOLTage:SLEW <NRf+>[suffix]
Parameter:
Refer to individual spec for valid numeric range.
Example:
SOUR:VOLT:SLEW 0.01 It sets the output voltage slew rate
to 0.01 volt/ms.
SOUR:VOLT:SLEW 10
It sets the output voltage slew rate
to 10 volt/ms.
Query Syntax:
SOUR:VOLT:SLEW? [{MAX/MIN}]
Return Parameter:
<NRf+> [Unit=Volt/ms]
Query Example:
SOUR:VOLT:SLEW?
It returns the voltage slew rate.
SOUR:VOLT:SLEW? MAX It return the max. voltage slew rate.
Return Example:
1.01
5.
SOURce: CURRent
Description:
Sets the output current (ampere).
Syntax:
SOURce:CURRent <NRf+>[suffix]
Parameter:
Refer to individual spec for valid numeric range.
Example:
SOUR:CURR 1
It sets the output current to 1 amps.
SOUR:CURR 60.00
It sets the output current to 60.00 amps.
Query Syntax:
SOUR:CURR? [{MAX/MIN}]
Return Parameter:
<NRf+> [Unit=Amp]
Query Example:
SOUR:CURR? It returns the current.
SOUR:CURR? MAX
It returns the max. current can be set.
Return Example:
1.00
Содержание 62000D Series
Страница 1: ......
Страница 2: ...Get more information by downloading Chroma ATE Solutions APP ...
Страница 8: ...vi ...
Страница 9: ...vii ...
Страница 10: ...viii ...
Страница 14: ......
Страница 18: ......
Страница 35: ...Overview 1 17 Figure 1 6 Dimension of 62000D 600 1200 1800 Models ...
Страница 36: ......
Страница 52: ......
Страница 54: ...Programmable Bidirectional DC Power Supply 62000D Series Operating and Programming Manual 3 2 Figure 3 2 ...
Страница 63: ...Manual Operation 3 11 Figure 3 13 Figure 3 14 ...
Страница 109: ...Manual Operation 3 57 _EXT ON SIGNAL EXT ON DISABLE EXT ON ENABLE Output Output Figure 3 85 ...
Страница 110: ......
Страница 117: ...Program Sequence 4 7 Figure 4 8 Figure 4 9 ...