Section 1: Introduction
CP2000-SB User Manual
3-47
020-100162-06 Rev. 1 (03-2014)
Admin: General and Admin: Lamp Menus
NOTE:
Installer login required.
From within the
Admin
menu, an installer can access three additional submenus not available to any other
user. These submenus are primarily for defining critical system parameters such as the projector's IP address,
lamp type, and user rights for remote access and data logging. Installers can also record minimum and
maximum footlambert readings to define a range from which other TPC lamp readings are interpolated, and
they can set whether Status menu temperatures appear in Celsius (default) or Fahrenheit. A typical
Admin:
General
submenu appears below.
Table 3.19 Summary of Admin: General Menu Options
ADMIN: GENERAL MENU OPTIONS
Projector IP
Address
Determines which projector the TPC controls, and always terminates in
10-99
. All four values (octets)
must be valid for your site. For example, perhaps you can use the default 192.168.206.
10
to control a
single-projector installation. Then use 192.168.206.
11
to control a second projector at that site,
192.168.206.
12
to control a third projector, and so on.
NOTE:
This menu does NOT define the projec-
tor's address
Image Orientation
Define the orientation of the screen relative to the projector.
Celsius Display
Choose Celsius or Fahrenheit temperature display for Status menu.
Remote Access
Define whether all users can access TPC functions remotely or not at all, or whether a login is required.
Data Logging
Define the extent of activity to record in an Ethernet-accessible TPC data log (default=Errors only). A
good data log can be helpful when troubleshooting, but use with caution- detailed logging will slow
TPC responses. Note that when the memory card becomes full, logging continues and simply writes
over the oldest entries.
Error Message
Enabled
When enabled, an error message will be sent via Ethernet whenever an alarm condition is encountered.
Figure 3-35 Admin: General Menu Options
Restrict who can
access the TPC
remotely:
• No access
• Login required
• Free Access
Define the extent of
data to be logged
• Errors
• Standard
• Detailed. NOTE:
Slows TPC response.
ID for projector
location on net-
work (Default
address shown.
Use valid address
for the site).
Define site
• Normal Front
• Inverted Rear
• Normal Rear
• Inverted Front
Toggle to use a
different lamp
mode & power
for each channel,
or to use one
setting for all.
Toggle to read
temp. in deg C or
deg F.
Send Alarm Window
messages via
Ethernet.
Содержание CP2000-SB
Страница 1: ...CP2000 SB U S E R M A N U A L 020 100162 06 ...
Страница 9: ......
Страница 15: ...1 6 CP2000 SB User Manual 020 100162 06 Rev 1 03 2014 Section 1 Introduction ...
Страница 155: ...8 8 CP2000 SB User Manual 020 100162 06 Rev 1 03 2014 Section 1 Introduction ...
Страница 157: ...8 10 CP2000 SB User Manual 020 100162 06 Rev 1 03 2014 Section 1 Introduction ...
Страница 173: ...A 16 CP2000 SB User Manual 020 100162 06 Rev 1 03 2014 Section 1 Introduction ...
Страница 197: ...B 24 CP2000 SB User Manual 020 100162 06 Rev 1 03 2014 Section 1 Introduction ...