6-8
CP2000-SB User Manual
020-100162-06 Rev. 1 (03-2014)
Section 1: Introduction
6.4.1 Lamp Replacement Procedure
NOTE:
For this procedure you will need a compatible Christie Xenon CDXL or CXL lamp as shown in
Section
8 Specifications
-never install a lamp intended for a different model or projector.
Warning! 1)
Make sure to
use the correct wattage lamp supplied by Christie.
2)
Lamp replacement is to be done by a qualified service
technician only.
3)
EXPLOSION HAZARD - Wear authorized protective clothing whenever the lamp door is
open! Never apply a twisting or bending force to the quartz lamp body.
Before You Begin
Read and follow all other general lamp precautions in
Section 6.1 Warnings and Guidelines
.
STEP 1: Turn Off Main AC
a. Allow the fans to run at least 10 minutes for cooling.
b. At the breaker panel on the projector, set the 3-phase
MAIN AC
circuit breaker to
OFF
.
Warning!
Never attempt to remove the lamp when it is hot. The lamp is under great pressure when hot
and may explode, causing personal injury and/or property damage. Allow to cool completely.
STEP 2: Turn Off Remaining Circuit Breakers
After allowing the fans to run for at least 10 minutes, turn OFF the remaining
INTERNAL
and
PROJEC-
TOR
circuit breakers located on the breaker panel of the projector.
STEP 3: Disconnect Projector from AC Supply
SHOCK HAZARD. Disconnect from all AC at ALL wall breakers.
STEP 4: Open the Lamp Door
With protective clothing and shield on, unlock the lamp door and open it. Refer to
Figure 2-5 Open Pro-
jector for Access, on page 2-5
. If desired, release the latch mechanism to remove the door entirely.
STEP 5: Open Cooling Compartment
Turn knob to open the inner lamp cooling compartment and reveal the cathode end (-) of the lamp.
STEP 6: Remove the Old Lamp and Inspect Reflector
a. Loosen set screws from negative/cathode (rear, 7/64") and positive/anode (front, 3/16") lamp connec-
tors. These screws are shown in
Figure 6-2
.
NOTE
:
Be sure to apply minimal torque and DO NOT
STRESS the quartz tube
.
b. Carefully slip the positive anode connector off the front of the lamp.
c. Handle the
cathode end only
. Unscrew the lamp from the rear connector and carefully remove it from
the projector.
Immediately
place the lamp inside the protective cover (saved from previous installa-
tion) and then seal it in a heavy carton on the floor where it cannot fall or be bumped.
Warning!
Han-
dle box with extreme caution. The lamp is hazardous even when packaged. Dispose of lamp box
according to safety regulations for your area.
d. With the lamp removed, visually inspect the reflector for dust. Clean if necessary as described in
Sec-
tion 6.3 Maintenance and Cleaning
.
Содержание CP2000-SB
Страница 1: ...CP2000 SB U S E R M A N U A L 020 100162 06 ...
Страница 9: ......
Страница 15: ...1 6 CP2000 SB User Manual 020 100162 06 Rev 1 03 2014 Section 1 Introduction ...
Страница 155: ...8 8 CP2000 SB User Manual 020 100162 06 Rev 1 03 2014 Section 1 Introduction ...
Страница 157: ...8 10 CP2000 SB User Manual 020 100162 06 Rev 1 03 2014 Section 1 Introduction ...
Страница 173: ...A 16 CP2000 SB User Manual 020 100162 06 Rev 1 03 2014 Section 1 Introduction ...
Страница 197: ...B 24 CP2000 SB User Manual 020 100162 06 Rev 1 03 2014 Section 1 Introduction ...