Section 1: Introduction
CP2000-SB User Manual
2-13
020-100162-06 Rev. 1 (03-2014)
2.1.6 Connecting to Power
Connecting the projector to your AC supply can vary according to the country in which the projector is
installed. The five scenarios are explained below. For any installation, always follow the electrical code for
your country.
Warning! 1)
Certified electrician required. Follow the Terminal Block 1 (TB1) Connections
diagram located on the inside of the pedestal.
2)
Installation of the pedestal’s conduit panel is MANDATORY
to avoid risk of electric shock causing bodily harm or even DEATH.
1. From the AC power source, route the 3-phase wires, single-phase and ground wires into one of the knock-
out holes located on the pedestal’s conduit panel. Use appropriately sized strain relief connectors with the
conduit panel. This will ensure adequate environmental sealing and prevent cables from wear and being
accidentally torn out.
Warning!
Use of the conduit panel is mandatory to prevent electric shock.
2. Connect the incoming AC ground lead directly to the frame ground stud on the floor of the pedestal
(
Figure 2-20
). Secure with both washers and nut provided, and ensure there are
no
other wires present at
this stud.
Warning!
Connect ground FIRST to reduce shock hazard from high leakage.
3. Refer to the Terminal Block 1 (TB1) Connections diagram provided on the inside of the pedestal door
(operator’s side). As described for your model and site, connect all available wires to the large terminal
block (TB1) located in the operator’s side of the pedestal.
NOTES:
1)
The Terminal Block 1 (TB1)
described below accommodates up to 6 AWG wire.
2)
For proper torque, a flat screwdriver with 4-6mm
blade is recommended.
3)
Ensure to refer to the Terminal Block 1 (TB1) Connections diagram located in
the pedestal.
Figure 2-20 Connect Incoming Ground Wire
Содержание CP2000-SB
Страница 1: ...CP2000 SB U S E R M A N U A L 020 100162 06 ...
Страница 9: ......
Страница 15: ...1 6 CP2000 SB User Manual 020 100162 06 Rev 1 03 2014 Section 1 Introduction ...
Страница 155: ...8 8 CP2000 SB User Manual 020 100162 06 Rev 1 03 2014 Section 1 Introduction ...
Страница 157: ...8 10 CP2000 SB User Manual 020 100162 06 Rev 1 03 2014 Section 1 Introduction ...
Страница 173: ...A 16 CP2000 SB User Manual 020 100162 06 Rev 1 03 2014 Section 1 Introduction ...
Страница 197: ...B 24 CP2000 SB User Manual 020 100162 06 Rev 1 03 2014 Section 1 Introduction ...