020-100162-06 Rev. 1 (03-2014)
Section 1: Introduction
3.5.2 TPC Status Menu
NOTE:
The
Status: System
menu described here is available to all users. For information about the
password-protected
Status: Server
,
Status: Diag
and
Status: Interrogator
menus, refer to
Section 3.11
Working with Servers and Diagnostics
.
Navigate the
Status
menu as you would Windows
Explorer
or
File Manager
, expanding or compressing
directories as desired by pressing the corresponding small square buttons. To see more of the
Status
menu,
drag the scroll bar up or down. This menu updates approximately every 30 seconds. A sample view of the
Status: System
menu is shown in
Figure 3-6
.
INFORMATION INDICATORS:
As shown in
Figure 3-6
, this blue symbol identifies basic informative
data describing the source connection, as well as certain non-critical historical/operational facts about the
projector and lamp. Such data does not trigger warnings or error conditions.
ENVIRONMENT / DIAGNOSTIC INDICATORS:
The small colored indicators or virtual LEDs for
environmental and diagnostic information are green during normal operation. These indicators can change to
indicate a warning (yellow) or critical error (red) status.
•
Yellow = Warning
Indicates an unusual environmental condition. For example, a temperature may be elevated and nearing its
upper limit-correct the problem by checking all cooling systems, turning OFF the projector and cooling if
necessary (make sure to follow the standard shut-down procedure). Service may be required in some cases.
•
Red = Error
Indicates that 1) the environment has a serious problem or 2) a specific electrical component is not detected
or does not appear to be functioning properly. In some cases, a module may need re-seating. In other cases,
service or replacement of a module may be required before the projector can resume normal operation.
Regardless, a red indicator requires immediate attention.
•
Diagnostics
Showing a question mark icon (
?
) indicates an unknown status caused by a problem during initialization. Try
re-booting the projector.
Note that if any of the small indicators are yellow or red, the main warning icon on the status bar changes
accordingly so that problems are also immediately detectable from other TPC menus. In addition, a full-screen
flashing red alarm window is triggered on the TPC for such problems as failed interlocks (mandatory), over-
temperature (optional), and fan problems (optional).
Содержание CP2000-SB
Страница 1: ...CP2000 SB U S E R M A N U A L 020 100162 06 ...
Страница 9: ......
Страница 15: ...1 6 CP2000 SB User Manual 020 100162 06 Rev 1 03 2014 Section 1 Introduction ...
Страница 155: ...8 8 CP2000 SB User Manual 020 100162 06 Rev 1 03 2014 Section 1 Introduction ...
Страница 157: ...8 10 CP2000 SB User Manual 020 100162 06 Rev 1 03 2014 Section 1 Introduction ...
Страница 173: ...A 16 CP2000 SB User Manual 020 100162 06 Rev 1 03 2014 Section 1 Introduction ...
Страница 197: ...B 24 CP2000 SB User Manual 020 100162 06 Rev 1 03 2014 Section 1 Introduction ...