Section 1: Introduction
CP2000-SB User Manual
2-7
020-100162-06 Rev. 1 (03-2014)
h.
CONNECT LAMP LEADS
:
1. Ensure the igniter door is open. From the ballast in the pedestal, route the main black and white
lamp leads through the nearby hole in the underside of the projection head. See
Figure 2-9
.
2. Route the
NEGATIVE (-) BLACK
lamp lead through the hole in the lamp cooling compartment
wall.
Warning! 1)
Ensure the PCB is directed toward the back and remains at least ¾” from the high-
voltage terminal (with braid connection).
2)
Route all igniter wires AWAY from 9-pin and 15-pin con-
nectors.
3)
Twist both ballast cables twice-per-foot.
3. Connect the
POSITIVE (+) WHITE
lamp lead to the
POSITIVE (+)
igniter terminal (3/4”
wrench). This terminal also has a small PCB attached—stack this on top of the lamp lead.
4. Close and lock the igniter door.
IN THE LAMP COOLING COMPARTMENT:
5. With the lamp door removed (refer back to
Figure 2-5
), turn the small knob and swing open the
lamp cooling compartment door (
Figure 2-10
).
Figure 2-9 Connect Lamp Leads
Figure 2-10 Accessing Cathode End
Содержание CP2000-SB
Страница 1: ...CP2000 SB U S E R M A N U A L 020 100162 06 ...
Страница 9: ......
Страница 15: ...1 6 CP2000 SB User Manual 020 100162 06 Rev 1 03 2014 Section 1 Introduction ...
Страница 155: ...8 8 CP2000 SB User Manual 020 100162 06 Rev 1 03 2014 Section 1 Introduction ...
Страница 157: ...8 10 CP2000 SB User Manual 020 100162 06 Rev 1 03 2014 Section 1 Introduction ...
Страница 173: ...A 16 CP2000 SB User Manual 020 100162 06 Rev 1 03 2014 Section 1 Introduction ...
Страница 197: ...B 24 CP2000 SB User Manual 020 100162 06 Rev 1 03 2014 Section 1 Introduction ...