OPERATION
Cine-IPM 2K User’s Manual
3-37
020-100164-01 Rev. 1 (01/08)
implemented immediately and remains in effect until it is changed again.
NOTE:
Make sure the Cine-IPM 2K is connected to the network before changing its IP
address.
PORT:
On some Ethernet networks, firewall restrictions may require that the port
number of the
Cine-IPM 2K
be changed from its default of 3002. If so, enter a new
valid port number here. NOTE: It is recommended you do not use port numbers
below 1000 as they are typically reserved by common IP applications.
SUBNET MASK AND DEFAULT GATEWAY:
The Subnet Mask and Default Gateway are
automatically assigned when DHCP is enabled. If a static IP address is used, assign it
first since the subnet mask is estimated after it is entered. The Default Gateway
allows you to specify the address of a local router, which enables the transmission of
data between separate IP networks.
NETWORK NAME:
Use this text box to assign a name to the projector to make it easier
to identify on the local network. This is typically recommended when DHCP is
enabled.
ArtNet Interface Settings –
SUBMENU
ArtNet is an Ethernet
communication protocol
that was developed by
Artistic License. It is used
for controlling
lighting/staging equipment
from a lighting console or
PC application. It is based
on the popular DMX512
control protocol.
ArtNet
SUBNET
:
This is the highest level address for a device. Typically it is set to 0.
ArtNet UNIVERSE
:
Each packet of data is broadcasted to all devices plugged into a
universe (up to 512 devices/channels).
ArtNet
ADVANCED MODE
:
If enabled, each projector listens for data on 64 channels
starting with the base channel. When advanced mode is not in use, the projector only
listens on 10 channels. You can squeeze more devices per universe when the
projector used fewer channels.
NOTE: The additional 54 functions are not currently
implemented and are reserved for future use.
ArtNet
BASE CHANNEL
:
When advanced mode is enabled, the projector listens to data
on 64 consecutive channels, or 10 consecutive channels when advanced mode is not
enabled. The projector processes requests that come on either 10 or 64 consecutive
channels beginning with the “base channel” defined here. The requests implement the
following functions:
Содержание CineIPM-2K
Страница 1: ...CineIPM 2K U S E R S M A N U A L 020 100164 01...
Страница 2: ......
Страница 26: ......
Страница 108: ......
Страница 109: ...Appendix B Remote Keypad Cine IPM 2K User s Manual B 1 020 100164 01 Rev 1 01 08 Figure B 1 Standard Remote Keypad...
Страница 110: ......
Страница 112: ...SERIAL COMMUNICATION CABLES C 2 Cine IPM 2K User s Manual 020 100164 01 Rev 1 01 08...
Страница 118: ......