2
-
4-2.Battery removal method
Do not replace the battery. Doing so might cause damage or malfunction. Do not remove the battery,
except when disposing the recorder.
(1) Open the key cover and remove the 2
retaining screws.
(2) Pull the bottom of the front display panel
toward you and lift up to remove the front
display.
(3) The front display is connected to PWB-A by 1
type of cable. Disconnect it.
(4) PWB-A is connected by 3 types of cables.
Disconnect them.
(5) Remove the 4 screws holding PWB-A, and
pull it out.
(6) Remove the screw of the mounting bracket
under PWB-C.
(7) Disconnect the connector for the power
switch cable on the left side of PWB-C and
pull out both PWB-B and –C as a set.
(8) Remove the 2 screws holding PWB-B and –C
together, and separate PWB-B from PWB-C.
(9) The battery holder is attached to the
underside of PWB-B. Lift the front of the
battery with a tool having a nonconductive tip
and pull the battery out of the holder.
Bracket
PWB-C
PWB-B
PWB-A
PWB-A
Display
panel