ENGLISH
.
Cod. 9828093300 00 - Vers. 04/2019 - 51
BEFORE PERFORMING ANY TYPE OF SERVICING, THE MACHINE MUST BE SHUT DOWN AND ISOLATED FROM THE
MAINS POWER AND COMPRESSED AIR DISTRIBUTION NETWORK.
15.5 ELECTRICAL CABINET FILTER CLEANING (IVR only)
- Shut down the machine using the button Ref. 1 Fig. 18: in this way, the machine will stop after the unloading run time.
-
Open the power disconnect switch Ref. 3 (for screw compressor) and Ref 3A (for dryer if present) Fig. 18.
- Remove the electrical cabinet filters Ref. 4 Fig. 18.
- Clean the electrical cabinet filters with a blast of air or wash with water,
Do not use solvents
- After this operation, remount the filters Ref. 4 Fig. 18.
AIR INTAKE PANEL FILTER CLEANING
- Shut down the machine using the button Ref. 1 Fig. 18: in this way, the machine will stop after the unloading run time.
-
Open the power disconnect switch Ref. 3 (for screw compressor) and Ref 3A (for dryer if present) Fig. 18.
- Remove the air intake panel filter Ref. 1 Fig. 18A.
- Clean the panel filter with a blast of air or wash with water,
Do not use solvents
- After this operation, remount the panel filter Ref. 1 Fig. 18A.