15.0 ROUTINE MAINTENANCE BY THE USER
BEFORE PERFORMING ANY TYPE OF SERVICING, THE MACHINE MUST BE SHUT DOWN AND ISOLATED FROM THE
MAINS POWER AND COMPRESSED AIR DISTRIBUTION NETWORK.
The service operations reported in this chapter can be carried out by the user.
More complex service operations requiring the intervention of professionally qualified personnel are reported in the chapter
GENERAL
ROUTINE MAINTENANCE Chap. 21.0
15.1 GENERAL NOTICES
15.2 MAINTENANCE PROGRAMME
◼
OPERATIONS THAT CAN ALSO BE PERFORMED BY THE USER
◼
◼
OPERATIONS THAT MUST BE PERFORMED BY TRAINED PERSONNEL; THESE OPERATIONS ARE ILLUSTRATED IN
PART “B” OF THIS MANUAL
These service intervals are recommended for non-dusty and well-ventilated environments.
For particularly dusty environments, the frequency of controls must be doubled.
Every day (after use)
◼
Check the automatic drainage of the condensate (dryer) and cyclone water separator (WSD -
optional) if present.
Every 50 running hours
◼
Drain the condensate from the oil catcher
◼
Check the oil level
◼
Clean the filter of the automatic condensate drain (dryer)
IVR only
◼
Clean the filters of the electrical cabinet
Every 500 hours
◼
Tightness of electrical cables (first 500 hours)
◼
Clean the air intake filter
◼
Clean the condenser coil (for dryer, if present)
◼
Clean the impurity filter of the automatic condensate drain (dryer)
Every 2000 hours
◼
Replace the intake filter
◼
◼
Replace the oil
◼
◼
Replace the oil filter
◼
◼
Re-tightening of electrical cables in cabinet
◼
◼
Temperature test for safety
◼
◼
Replace the impurity filter of the automatic condensate drain (dryer)
Every 4000 hours
◼
◼
Clean the finned surface of the air-oil cooler
◼
◼
Replace the oil separator filter
◼
◼
Replace the air intake panel filter
◼
◼
Maintenance kit of automatic condensate drain (dryer)
IVR only
◼
Replace the air intake filters of the electrical cabinet
IVR only
◼
◼
Greasing of electric motor bearings
Every 8000 hours
◼
◼
Change check valve
◼
◼
Intake valve service kit
◼
◼
Servicing of oil return valve and inspection of oil tubes
◼
◼
Minimum pressure valve and thermostatic valve service kit
◼
◼
Change the oil (if RXD used)
IVR only
◼
◼
Visual inspection of elastic element of motor-compressor coupling
Every 24000 hours
◼
◼
Kit revision of the compressor unit
◼
◼
Service kit Motor (bearings)
Oil specifications:
It is highly recommended to us
e the manufacturer’s original lubricants. These are the result of years of industry experience and research.
See the Routine maintenance programme section for recommended replacement intervals and consult the list of spare parts for information
on the part number.
DO NOT MIX LUBRICANTS OF DIFFERENT BRANDS OR DIFFERENT TYPES INSOFAR AS THEY MAY NOT BE
COMPATIBLE AND OIL MIXES MAY HAVE INFERIOR PROPERTIES.