ENGLISH
.
Cod. 9828093300 00 - Vers. 04/2019 - 29
Example
The screen shows the number <d.1>, the unit of measure in use <hrs> and the symbol relative to the running hours. Press the Enter key (5) to bring
up the effective running hours.
Overview of screens
Digital input screens
Name
Associated topic
<d.in>
Digital input status
< Spd >
Motor speed
<d.1>
Running hours (hours or x 1000 hours)
<d.2>
Motor starts (x 1 or x 1000)
<d.3>
Module hours (hours or x 1000 hours)
<d.4>
Loading hours (hours or x 1000 hours)
<d.5>
Load relay (x 1 or x 1000)
<d.6>
Service timer reading (hours or x 1000 hours)
<d.7>
Number of emergency stops
<d.8>
Actual programme version
Parameter screens
Name
Associated topic
<P.1>
Choice of local, remote or LAN control
<P.2>
Node ID setting for LAN control and channels for Mk 4
and Mk 5
<P.3>
IP address, gateway and subnet mask setting
<P.4>
Pressure band setting
<P.5>
Pressure band selection setting
<P.6>
Enable remote selection of pressure
band
<P.7>
Reduce maximum motor speed %
<P.8>
Hours to first service interval
<P.9>
Unit of temperature setting
<P.10>
Unit of pressure setting
<P.11>
Enable automatic restart after voltage failure
<P.12>
Enable password
Protection screens
Name
Associated topic
<Pr.2>
Protection screens
Test screens
Name
Associated topic
<t.1>
Display test
<t.2>
Safety valve test
<t.3>
Enable bearing greasing