ENGLISH
.
Cod. 9828093300 00 - Vers. 04/2019 - 45
Regulation menu (Settings)
Function: in fixed speed compressors, it is possible to programme two different pressure bands. From this menu it is also possible to select
the active pressure band.
Procedure: from the Main screen (see main Screen), move the cursor onto the Menu action button and press the Enter key. Using the scroll
keys, move the cursor onto the Regulation icon (see below):
Press the Enter key. A screen will appear similar to the one shown below:
The screen shows the effective unloading and loading pressure settings for both pressure bands.
To change the settings, move the cursor onto the Modify action button and press the Enter key. The following screen appears:
The first row of the screen is highlighted. Use the scroll keys to highlight the setting to be changed and press the Enter key. The following
screen appears:
The upper and lower limits of the setting are shown in grey, the current setti
ngs are shown in black. Use the scroll key ↑ or ↓ to change the
settings as needed and press Enter to confirm.
If necessary, change the other settings following the same procedure explained above.
(1)
Regulation/Settings
(2)
Unloading pressure 1
(3)
Loading pressure 1
(4)
Unloading pressure 2
(5)
Loading pressure 2
(6)
Modify