Procedure
Starting from a sub-menu screen (see Modification of general settings), using the scroll keys, move the cursor onto the General icon (see
below).
Press the Enter key. A screen will appear similar to the one shown below:
A screen similar to the one shown above appears, with the first item (Language) selected. Use the ↓ key to select the setting
to modify and
press the Enter key. To confirm the changes, press the Enter key. A pop-
up screen appears. Use the ↑ or ↓ key to s
elect the requested
parameter and press the Enter key to confirm.
Terminology
Term
Explanation
ARAVF
Automatic restart after voltage failure.
Power return time
The period of time within which the voltage must be restored for automatic restart. It is accessible if automatic
restart is active. To activate the automatic restart function, consult the customer centre.
Restart delay
This parameter allows compressor restarts to be programmed in such a way that they don’t occur simultaneously
after a voltage failure condition (ARAVF active).
Screw compressor outlet
The regulator does not accept conflicting settings. For example, if the alarm level is programmed at 95 ˚C (203
˚F), the minimum shutdown level will become 96 ˚C (204 ˚F). The recommended differe
nce between the alarm
level and shutdown level is 10 °C (18 °F).
Shutdown delay
This is the period of time during which the signal must persist before the compressor shuts down. Should it be
necessary to change this setting to another value, contact the customer centre.
Minimum stop time
When the compressor shuts down, it remains stopped for the minimum stop time regardless of the compressed
air distribution network pressure. Contact your supplier if a value less than 20 seconds is required.
Unloading pressure /
loading pressure
The regulator does not accept illogical settings. For example, if the programmed unloading pressure is 7.0 bar(e)
(101 psi(g)), the maximum loading pressure becomes 6.9 bar(e) (100 psi(g)). The recommended minimum
difference between the loading and unloading pressure is 0.6 bar (9 psi(g)).
(1)
General
(2)
Language in use
(3)
Time
(4)
Date
(5)
Date format
(6)
Modify