Fault code Fault
Possible cause
Correcting measures
42
Brake resistor
overtemperature
Brake resistor over temperature
protection has detected too heavy
braking
Set the deceleration time longer. Use
external brake resistor.
50
Analogue input Iin
< 4mA (selected
signal range 4 to
20 mA)
Current at the analogue input is <
4mA.
•
control cable is broken or loose
•
signal source has failed
Set the deceleration time longer. Use
external brake resistor.
Check the current loop circuitry.
51
External fault
Digital input fault.
52
Keypad
communication
fault
The connection between the control
keypad and the frequency converter
is broken.
Check keypad connection and
possible keypad cable.
Instruction book
82
2920 1804 00
Содержание CPF 175
Страница 1: ...CPF 175 CPVS 175 Instruction book ...
Страница 2: ......
Страница 7: ...11 Declaration of conformity 148 Instruction book 2920 1804 00 5 ...
Страница 15: ...2 2 Air and oil system Flow diagrams Flow diagram air cooled compressor Instruction book 2920 1804 00 13 ...
Страница 18: ...Flow diagram water cooled compressor with modulating control Instruction book 16 2920 1804 00 ...
Страница 33: ...Menu structure for fixed speed compressors Instruction book 2920 1804 00 31 ...
Страница 34: ...Menu structure for variable speed compressors Instruction book 32 2920 1804 00 ...
Страница 60: ...Fixed speed compressors Instruction book 58 2920 1804 00 ...
Страница 72: ...Fixed speed compressors Instruction book 70 2920 1804 00 ...
Страница 104: ...Electrical connections for IEC variable speed compressors Instruction book 102 2920 1804 00 ...
Страница 105: ...Electrical connections for CSA UL fixed speed compressors Instruction book 2920 1804 00 103 ...
Страница 151: ......
Страница 152: ...No 2920 1804 00 2012 08 ...