Structure
Definition
Minimum
Maximum
Signifies that an error will be
generated if the temperature
crosses 110°C (230 °F).
> value of
fixed
parameter
120 °C (248 °F)
Corresponding to the
temperature (105 °C (221 °F))
at which a pre-alarm will be
displayed to inform the operator
that a protection limit is being
approached.
0°C (32 °F)
< value of the
above
parameter
Time after the starting of the
compressor when this
protection becomes active.
0 s
120 s
An error shall be generated if
the temperature crosses the
maximum threshold (110 °C
(230 °F)) plus 3 seconds (value
of this parameter).
0 s
10 s
Protection against the wrong
direction of rotation, no
parameter is modifiable but the
protection is active.
Delta P
Protections on the calculated analog input Delta P. This dummy analog input corresponds to the difference
between the pressure in the internal tank and the pressure at the compressor outlet.
Instruction book
2920 1804 00
61
Содержание CPF 175
Страница 1: ...CPF 175 CPVS 175 Instruction book ...
Страница 2: ......
Страница 7: ...11 Declaration of conformity 148 Instruction book 2920 1804 00 5 ...
Страница 15: ...2 2 Air and oil system Flow diagrams Flow diagram air cooled compressor Instruction book 2920 1804 00 13 ...
Страница 18: ...Flow diagram water cooled compressor with modulating control Instruction book 16 2920 1804 00 ...
Страница 33: ...Menu structure for fixed speed compressors Instruction book 2920 1804 00 31 ...
Страница 34: ...Menu structure for variable speed compressors Instruction book 32 2920 1804 00 ...
Страница 60: ...Fixed speed compressors Instruction book 58 2920 1804 00 ...
Страница 72: ...Fixed speed compressors Instruction book 70 2920 1804 00 ...
Страница 104: ...Electrical connections for IEC variable speed compressors Instruction book 102 2920 1804 00 ...
Страница 105: ...Electrical connections for CSA UL fixed speed compressors Instruction book 2920 1804 00 103 ...
Страница 151: ......
Страница 152: ...No 2920 1804 00 2012 08 ...