Alarm messages
Description
Main screen
message
Error menu
message
Solution
The approximate loss of load
has exceeded the alarm
threshold but remains less than
the maximum threshold. (P
tank - P output)
AC Approach 1.5
bar/22 psi Shd
Max. 1.3 bar/19
psi
Verify de-oiler loss of load, verify de-
oiling, and replace de-oiler if
necessary. Verify the VPM.2
The approximate loss of load
has exceeded the alarm
threshold but remains less than
the maximum threshold. (P
tank - P output)
Delta P 1.6 bar/23
psi Shdw Max 1.3
bar/19 psi
Verify de-oiler loss of load, verify de-
oiling, and replace de-oiler if
necessary. Verify the VPM.
Dryer frozen. Dryer
temperature less than - 1
°C/-33.8 °F. The dryer is
stopped and restarts at LAT =
7 °C/44.6 °F
** Warning **
Dryer LAT -5 °C/
41 °F Min. frze -1
°C/33.8 °F
Verify ambient temperature.Verify
correct operation of the drier. (HGBV
+ PS)
Dryer temperature too high.
The alarm will disappear when
the temperature drops
** Warning **
Dryer LAT Dewp
Not normal
Dryer temperature too high.
The alarm will disappear when
the temperature drops
** Warning **
Dryer LAT 232 °C/
449.6 °F Max.
alarm 25 °C/77 °F
Error messages
Description
Main screen
message
Error menu
message
Solution
High temperature error
Elem. outlet 113
°C/235 °F Shd
Max. 110 °C/230
°F
The oil temperature has exceeded the
high error threshold (110 °C/230 °F )
Rotation direction. The Airlogic
has calculated that the oil
temperature has not increased
sufficiently during starting and
therefore the compressor turns
in the wrong direction.
Elem. outlet 88
°C/190.4 °F Rota
Verify the direction of rotation of the
compressor and the power supply
cable. Down-powering required for
reset + phase changes. Do not carry
out too many tests.
The temperature sensor
measures a temperature out of
the normal range (-40 °C/340
°C) (-104 °F/644 °F)
Elem. outlet ******
°C/°F Shd Max.
110°C/230°F
Verify connections, condition of
cables. Disconnect the sensor. It
should then indicate the ambient
temperature. It is also possible to
measure the resistance indicated by
the sensor and to verify whether or not
it has drifted, using the tables.
The tank pressure sensor
measures a pressure outside
the normal range (0/17 bars)
(0/246.5 PSI) during operation
under load
Receiver Press.
****** bar/psi Shd
Max. 9.0 bar/
130.5 psi
Verify connections, condition of
cables. Disconnect the sensor. It
must then indicate 0 bar/0 psi. Verify
the sensor for correct operation.
Instruction book
2920 1804 00
77
Содержание CPF 175
Страница 1: ...CPF 175 CPVS 175 Instruction book ...
Страница 2: ......
Страница 7: ...11 Declaration of conformity 148 Instruction book 2920 1804 00 5 ...
Страница 15: ...2 2 Air and oil system Flow diagrams Flow diagram air cooled compressor Instruction book 2920 1804 00 13 ...
Страница 18: ...Flow diagram water cooled compressor with modulating control Instruction book 16 2920 1804 00 ...
Страница 33: ...Menu structure for fixed speed compressors Instruction book 2920 1804 00 31 ...
Страница 34: ...Menu structure for variable speed compressors Instruction book 32 2920 1804 00 ...
Страница 60: ...Fixed speed compressors Instruction book 58 2920 1804 00 ...
Страница 72: ...Fixed speed compressors Instruction book 70 2920 1804 00 ...
Страница 104: ...Electrical connections for IEC variable speed compressors Instruction book 102 2920 1804 00 ...
Страница 105: ...Electrical connections for CSA UL fixed speed compressors Instruction book 2920 1804 00 103 ...
Страница 151: ......
Страница 152: ...No 2920 1804 00 2012 08 ...