Information messages
Description
Main screen
message
Error menu
message
Solution
Permissible starting conditions
not reached
Process Starts
The machine is verifying the following
parameters (time is adjustable
depending on whether the dryer is
enabled or disabled) : -ambient
temperature measured by Element
outlet temperature (>2 °C/35.6 °F)-
tank pressure (<1.5 bar/21.7 psi)-
Dryer LAT (correct) , dryer
temperature>-1 °C/-33.8 °F
The machine is under load. It is
automatically regulated by its
internal sensor.
Auto Loaded
The compressor is stopped, as
well as the motor.
Compressor Off
The compressor as well as the
motor are stopped, but could
re-start at any time.
Motor Stopped
The machine is operating
under no load. It is
automatically regulated by its
internal sensor.
Auto Unloaded
Stopping is requested. The
machine switches to no load.
Progr. stop
The temperature sensor
measures a temperature out of
the normal range (-40 °C/340
°C) (-104 °F/644 °F)
****** * Sensor
Error*
Verify connections, condition of
cables. Disconnect the sensor. It
should then indicate the ambient
temperature. It is also possible to
measure the resistance indicated by
the sensor and to verify whether or not
it has drifted, using the tables.
The tank pressure sensor
measures a pressure outside
the normal range (0/17 bar)
(0/246.5 psi)
* Sensor Error*
Verify connections, condition of
cables. Disconnect the sensor. It
must then indicate 0 bar/0 psi. Verify
the sensor for correct operation.
The pressure regulation
sensor (machine output),
measures a pressure outside
the normal range (0/17 bar)
(0/246.5 psi)
* Sensor Error*
Verify connections, condition of
cables. Disconnect the sensor. It
must then indicate 0 bar/0 psi. Verify
the sensor for correct operation.
No load switch-over command
given by the Airlogic (max.
internal pressure of the
machine reached) , whereas
the machine is controlled by an
external regulation device
(Digital, LAN…), giving it the
under load operating
command.
Unload: Overpr.
Adjustment of the external operating
order to a lower threshold than the
maximum permissible pressure of the
machine.
Remote stopping/starting
Remote control
Instruction book
2920 1804 00
79
Содержание CPF 175
Страница 1: ...CPF 175 CPVS 175 Instruction book ...
Страница 2: ......
Страница 7: ...11 Declaration of conformity 148 Instruction book 2920 1804 00 5 ...
Страница 15: ...2 2 Air and oil system Flow diagrams Flow diagram air cooled compressor Instruction book 2920 1804 00 13 ...
Страница 18: ...Flow diagram water cooled compressor with modulating control Instruction book 16 2920 1804 00 ...
Страница 33: ...Menu structure for fixed speed compressors Instruction book 2920 1804 00 31 ...
Страница 34: ...Menu structure for variable speed compressors Instruction book 32 2920 1804 00 ...
Страница 60: ...Fixed speed compressors Instruction book 58 2920 1804 00 ...
Страница 72: ...Fixed speed compressors Instruction book 70 2920 1804 00 ...
Страница 104: ...Electrical connections for IEC variable speed compressors Instruction book 102 2920 1804 00 ...
Страница 105: ...Electrical connections for CSA UL fixed speed compressors Instruction book 2920 1804 00 103 ...
Страница 151: ......
Страница 152: ...No 2920 1804 00 2012 08 ...