The modification of this parameter is justified only if a change is made in the transmission ratio. No other
reason can justify increasing the value of this parameter.
Structure
Definition
Minimum
Maximum
This menu has only one
parameter that allows
limiting the maxi pressure
serving as the limit of all
the user pressure settings
(loading, unloading
pressure).
7.5 bar (108 psi) 17 bar (246.5 psi)
Motor Rotations (only for fixed speed compressors)
The parameters of this menu allow defining the protection against the wrong direction of motor rotation. This
protection intervenes only after turning on the power to the AIRLOGIC
®
controller.
At the time of first loading of the compressor, after turning on the power, the controller measures the
temperature increase at the outlet of the compression block during a certain time. If during this time interval
Temp Duration, the temperature has not increased more than the value of the parameter Diffr.Temp., it is
considered that the compressor is running in the wrong direction.
For deactivating this error message, it is necessary to switch off the power to the compressor, interchange two
of the three power supply phases to the motor and switch on the power again.
Setting these two parameters to zero deactivates this protection.
Structure
Definition
Minimum
Maximum
Period, after the first
passage in load (after
restarting the power),
during which the
temperature is scanned.
0 s
255 s
Minimum temperature
variation that should be
exceeded during Temp.
Duration for considering
that the motor is rotating
in the wrong direction.
-3277 °C (-590.6
°F)
3277 °C (5930.6
°F)
3.16 Configuration user menu
Description
Configuration menu for numerous parameters, making it possible to adapt signals to the standards of the
customer: date, time, unit, language, etc …
Instruction book
64
2920 1804 00
Содержание CPF 175
Страница 1: ...CPF 175 CPVS 175 Instruction book ...
Страница 2: ......
Страница 7: ...11 Declaration of conformity 148 Instruction book 2920 1804 00 5 ...
Страница 15: ...2 2 Air and oil system Flow diagrams Flow diagram air cooled compressor Instruction book 2920 1804 00 13 ...
Страница 18: ...Flow diagram water cooled compressor with modulating control Instruction book 16 2920 1804 00 ...
Страница 33: ...Menu structure for fixed speed compressors Instruction book 2920 1804 00 31 ...
Страница 34: ...Menu structure for variable speed compressors Instruction book 32 2920 1804 00 ...
Страница 60: ...Fixed speed compressors Instruction book 58 2920 1804 00 ...
Страница 72: ...Fixed speed compressors Instruction book 70 2920 1804 00 ...
Страница 104: ...Electrical connections for IEC variable speed compressors Instruction book 102 2920 1804 00 ...
Страница 105: ...Electrical connections for CSA UL fixed speed compressors Instruction book 2920 1804 00 103 ...
Страница 151: ......
Страница 152: ...No 2920 1804 00 2012 08 ...