Description
Main screen
message
Error menu
message
Solution
Control carried out via a LAN
type network
LAN control
The Airlogic is in remote
control mode, internal
regulation and receives a
remote emptying command.
Manual Unload
The regulator is starting the
motor but cannot yet give the
signal to the Airlogic
concerning motor speed.
Motor starting
Inverter messages (variable speed compressors)
Fault code Fault
Possible cause
Correcting measures
1
Overcurrent
Frequency converter has detected
too high a current (>4*In) in the motor
cable:
•
sudden heavy load increase
•
short circuit in motor cables
•
unsuitable motor
Check loading. Check motor size.
Check cables.
2
Overvoltage
The DC-link voltage has exceeded
the limits defined in table 4.2 (NX
manual)
•
too short a deceleration time
•
high over voltage spikes in supply
Make the deceleration time longer.
3
Earth fault
Current measurement has detected
that the sum of motor phase current
is not zero.
•
insulation failure in cables or
motor
Check motor cables and motor.
5
Charging switch
The charging switch is open, when
the START command has been
given.
•
faulty operation
•
component failure
Reset the fault and restart. Should the
fault re-occur, contact the distributor
near to you.
6
Emergency stop
Stop signal has been given from the
option board.
7
Saturation trip
Very high overload. Defective
component
Cannot be reset from the keypad.
Switch off power. If this does not help,
contact the distributor near to you.
8
Unknown fault
The frequency converter
troubleshooting system is unable to
locate the fault.
Reset the fault and restart. Should the
fault re-occur, contact the distributor
near to you.
9
Undervoltage
DC-link voltage is under the voltage
limits.
•
most probable cause: too low a
supply voltage
•
frequency converter internal fault
In case of temporary supply voltage
break, reset the fault and restart the
frequency converter. Check the
supply voltage. If it is adequate, an
internal failure has occurred. Contact
the distributor near to you.
Instruction book
80
2920 1804 00
Содержание CPF 175
Страница 1: ...CPF 175 CPVS 175 Instruction book ...
Страница 2: ......
Страница 7: ...11 Declaration of conformity 148 Instruction book 2920 1804 00 5 ...
Страница 15: ...2 2 Air and oil system Flow diagrams Flow diagram air cooled compressor Instruction book 2920 1804 00 13 ...
Страница 18: ...Flow diagram water cooled compressor with modulating control Instruction book 16 2920 1804 00 ...
Страница 33: ...Menu structure for fixed speed compressors Instruction book 2920 1804 00 31 ...
Страница 34: ...Menu structure for variable speed compressors Instruction book 32 2920 1804 00 ...
Страница 60: ...Fixed speed compressors Instruction book 58 2920 1804 00 ...
Страница 72: ...Fixed speed compressors Instruction book 70 2920 1804 00 ...
Страница 104: ...Electrical connections for IEC variable speed compressors Instruction book 102 2920 1804 00 ...
Страница 105: ...Electrical connections for CSA UL fixed speed compressors Instruction book 2920 1804 00 103 ...
Страница 151: ......
Страница 152: ...No 2920 1804 00 2012 08 ...