www.chartdosers.com
PN 15920
Page 41 of 43
Condition: No liquid from the dosing head.
Possible Causes
Actions
There is insufficient liquid inside the UltraDoser
unit.
Open the valve (counter-clockwise direction) on
the Dura-Cyl
®
Liquid Cylinder.
The unit is disabled.
Switch the Dose Enable switch to the “I” position.
The nozzle is frozen shut.
Remove, clean, and re-install the nozzle (see page
36).
There is insufficient GN
2
to the dosing head valve.
Check the level of GN
2
at the source. If the level is
empty or low, replace.
The speed sensor is not functioning
Check the speed sensor is operating correctly and
is sending a signal to the controller.
5. Condition: The dosing valve alarm is displayed.
Possible Causes
Actions
The dosing valve assembly is not moving.
Check the pneumatic pressure There must be more
than 60 psi (4.14 bar) to have the dosing valve
function correctly.
Check the confirm sensor for correct placement.
6. Condition: The speed sensor alarm is displayed.
Possible Causes
Actions
The speed sensor has been dislodged.
Check speed sensor connections.
The speed sensor has malfunctioned.
Replace speed sensor.
7. Condition: The system is in speed compensated mode but is missing bottles.
Possible Causes
Actions
The container sensor is not detecting a container.
Check sensor connections. If necessary, replace
sensor.
The speed sensor has been dislodged.
Check speed sensor connections.
The speed sensor has malfunctioned.
Replace speed sensor.
**Note: The UltraDoser system will continue to dose even if there is a speed sensor fault. The 500S
controller displays the last known speed and compensates per that speed.