Fixed Delay Mode (FXDD)
In Fixed Delay mode, the operator inputs the “Dose Time” and the “Fixed Speed Mode Delay”. When the
system detects a bottle (or container), the UltraDoser will dose per the dose time after the fixed speed mode
delay time passes. In this mode the system only requires a container sensor to detect bottles (or containers).
The 500S controller is preset at the factory to run in Fixed Delay mode; 1 millisecond (msec) dose delay with
40 millisecond (msec) dose duration.
1.
Turn the 500S controller ON.
2.
On the front of the 500S controller box, place the Dose Enable switch in the disable mode (0).
3.
From the Home screen press ESC to go to the System Functions screen (image below).
4.
Use the arrow key
▲
or
▼
to highlight Setup Mode. Press ENTER to select.