Speed Compensated Mode (SCMP)
In Speed Compensation mode, the 500S controller automatically adjusts the time delay from the time the
UltraDoser
®
LN
2
Dosing System senses the bottle (or container) to when it doses based on the speed of the line.
The operator must enter several parameters and install a container sensor and a speed sensor (see page 19 for
additional information). The 500S controller will automatically change to continuous dosing at 500 containers
per minute (cont/min).
1.
Turn the 500S controller ON.
2.
On the front of the 500S controller box, place the Dose Enable switch in the disable mode (0).
3.
From the Main screen press ESC to go to the System Functions screen (image below).
4.
Use the arrow key
▲
or
▼
to highlight Setup Mode. Press ENTER to select.
5.
Use the arrow key
▲
to go to the Fixed Speed Mode Delay screen (image below). Press ENTER to
highlight the digit before ‘msec’.