Installing the Nozzle
Three nozzles are supplied with the UltraDoser
®
500S LN
2
Dosing System – 0.040”, 0.050”, and 0.060”.
Custom sizes may be ordered from Chart.
1.
Remove the dosing head heater.
2.
Select a nozzle.
3.
Insert the nozzle into the nozzle tool, threads out (Image 1).
4.
Thread the nozzle into the dosing head area in a clockwise direction (Image 2 & 3). Do not over torque.
5.
Re-apply the dosing head heater.
CAUTION: Never use an ice-pick, screwdriver, torch, or similar devices on the dosing head (Image 2). The
ribs of the internal bellows are a thin walled metal and the hole on the outer ring of the dosing head is a positive
pressure port to help keep moisture out and ice from forming. High heat and puncture holes will destroy the
vacuum insulation and VOID WARRANTY.
Positioning the Dosing Head
The dosing head should be directly over the bottle (or container) opening. The dosing head is typically installed 1/2”
- 3/4” above the bottle (or container) opening. The UltraDoser unit must be manually adjusted to accommodate
different sized bottles (or containers) running on the same production line.