11.
Use the arrow key
▲
or
▼
to go to the Speed Pulses per Container screen (image below). Press ENTER
to highlight the value.
IMPORTANT: This is a critical parameter of the system and care should be taken to input the correct value.
The number of pulses does not have to be a whole number.
Determining Speed Pulses per Container
Speed pulses per container can be determined by observing the light pulses on both the container and speed
sensors. If there are three speed light pulses per container pulse, the speed pulses per container is 3.
In cases where the lights on the container and speed sensors are not visible, the 500S controller can be opened
and light pulses on inputs IO.1 (Speed Sensor) and IO.2 (Container Sensor) can be counted.
12.
Use the arrow key
▲
or
▼
to change the value. Press ENTER when the desired value is shown; range is
1 to 12. The speed pulse is now set.