13-11-614 Page 69
Message
Action Needed
WATER PRESS
See “External Device”, page 28, for details.
ZERO XDUCER
Signal voltage has fallen too low at transducer: (A) Final discharge, (B) Water
Injection, or (C) Reservoir. This error is usually the result of the transducers
being improperly zeroed. Disconnect the air lines to the transducers and follow
the procedure indicated in the adjustment instructions.
CONTROLS TROUBLESHOOTING GUIDE
The following are recommended service actions. Observe all instructions noted elsewhere in this manual.
All electrical service is to be performed only by a qualified electrician.
Message
Action Needed
No display,
compressor stopped
Check incoming power to the compressor unit. Ensure that the disconnect is
on and that fuses have not blown (or circuit beaker tripped). If power is being
properly supplied to the control box, check the fuses located at the fan starter,
the control transformer fuses, and the fuse located on the AUTO SENTRY W
keypad chassis.
Compressor will not
start
To operate, the controller must be placed into an operating mode (e.g.
AUTO); press the [STOP/RESET] key to put the control into the READY
state, then start by pressing the [START] key. In AUTOMATIC and
SEQUENCE modes, compressors will not start until the pressure drops below
the load pressures.
Display indicates
“NOT BLOWN DOWN”
The controller prevents attempts to start the main motor if the reservoir
pressure is over 5 psig. Pressure continues to be relieved from the reservoir
while this message is on, and the compressor will start automatically after the
pressure has dropped. If this message remains with NO pressure in the
reservoir, follow the transducer zeroing procedure found in the controls
adjustment section.
Display indicates
“REMOTE STOP”
The controller is provided with an input for user-furnished remote controls.
This display indicates that 120 volt is removed from terminal 23 of the
terminal strip. Check all connections of the expansion board, or the
customer-provided controls, if applicable
Display indicates
“SHUTDOWN”
If the display indicates “SHUTDOWN”, refer to the shutdown troubleshooting
section for assistance. In addition to the messages shown, there are several
internal and system diagnostics performed by the controller. Consult the
factory for additional assistance.
Содержание ROTORCHAMP EWF99C-100
Страница 7: ...13 11 614 Page 7 Figure 1 2 PACKAGE ILLUSTRATION AIR COOLED 309EWF797 A Ref Drawing ...
Страница 8: ...13 11 614 Page 8 Figure 1 3 PACKAGE ILLUSTRATION WATER COOLED 310EWF797 A Ref Drawing ...
Страница 9: ...13 11 614 Page 9 Figure 1 4 AIR COOLED SCHEMATIC 307EWF797 A Ref Drawing ...
Страница 10: ...13 11 614 Page 10 Figure 1 5 WATER COOLED SCHEMATIC 308EWF797 A Ref Drawing ...
Страница 29: ...13 11 614 Page 29 Figure 4 2 FLOW CHART FOR SETUP PROGRAMMING 300EWC1255 Ref Drawing ...
Страница 43: ...13 11 614 Page 43 303EWF546 A Ref Drawing Page 2 of 2 ...
Страница 44: ...13 11 614 Page 44 Figure 4 5 WIRING DIAGRAM WYE DELTA WITH EXPANSION BOARD 304EWF546 A Ref Drawing Page 1 of 2 ...
Страница 45: ...13 11 614 Page 45 304EWF546 A Ref Drawing Page 2 of 2 ...
Страница 46: ...13 11 614 Page 46 Figure 4 6 WIRING DIAGRAM FULL VOLTAGE LESS STARTER 305EWF546 A Ref Drawing Page 1 of 2 ...
Страница 47: ...13 11 614 Page 47 305EWF546 A Ref Drawing Page 2 of 2 ...