-64-
3051 - 3101 - 3151 - 040/22 - 100/28 - 150/36
© C.F.M. S.p.A.
Tutti i diritti riservati
All rights reserved
1- Clogged primary filter
1- The vacuum suddenly stops
1- Clogged suction pipe
1- Motor protector tripper
Remedies
Fault
2- The filter is torn
2- Inadequate filter
2- Dust leaks from the vacuum
3- Incorrect connection to the
electricity main
3- The vacuum blows instead
of sucking
4- Electrostatic current on the
vacuum
4- Non existent or inefficient
earthing
Causes
3- Remove the plug and
invert two of the live
wires. Consult paragraph
5.3
4- Check all earth con-
nections. Particularly
check the suction inlet
fitting.
Lastly, the pipe must be
strictly antistatic
1- Shake the filter. Replace
it if this is not sufficient
1- Check the suction pipe
and clean it
1- Check the setting.
Check the power draw of
the motor. Contact an
authorized after-sales
service centre if neces-
sary
2- Change it for another of
identical category
2- Change it for another of
suitable category and
check