10
06/09/07
Model
Output
Burner
Pump
Air
Firing CO
²
% Smoke
Flue Gas
Nozzle
Pressure Shutter Rate l/h
US/GPH
kW Btu/h
Type
Head
/ Angle
Bar psi
Temp
º
C
x 1000
Setting
Gross
110
26.4
90
443T58
Fixed
0.75x60W 7.1
105 3.0
2.88
12
0 - 1
200
180
44
150
459T55
4
1.10x60W 9.2
135 4.0
4.84
12
0 - 1
220
220
51
175
464T55
2
1.25x60W 10.2 150 3.5
5.82
12
0 - 1
240
280
Not Available
3:6.2 Class D, Gas Oil NOTE: Low Level discharge is NOT allowed
Gas Oil Conversion Components
Model Nozzel
Pre-Heater Conversion Kit Bottom Baffle
110 SPCOH2/009 SPCOH2/008
Not required As Supplied
180 SPCOH2
SPCOH001
Not required As Supplied
220 SPCOH26
Not required
Not required As Supplied
280
Not Available
4: INSTALLATION
4:1 STANDARDS & REGULATIONS
The installation of the Heater must comply with
latest edition of :-
BS 5410: Oil Installations
Pt 1 under 44kW
Pt 2 over 44kW
BS 5449: Forced circulation hot water central
heating systems for domestic premises.
BS 4543: Pt. 1 & 3 Factory made insulated chimneys.
BS 7671: Electrical Wiring Regulations.
BS 7593: Treatment of water in Hot Water heating
systems
BUILDING REGULATIONS.
Part J & G England and Wales
Part F Section lll Scotland
Part L Northern Ireland
The Control of Pollution (Oil) Regulations
Oil Heaters should be installed in accordance with
good practice as recommended by OFTEC (Section.
2:4).
4:2 HEATER CONTROL
This Heater uses a control specifically designed for
it and it has the following features:
A highly accurate Pool Thermostat , 16°C to 41°C
(60°F to 106°F)
A Boiler Thermostat. Fixed for Pool, 84°C, variable
for Heating 60 - 82°C.
A Frost Thermostat which runs the Internal and
Pool Pump at 3°C or below but then fires the
Heater alone if the temperature has not risen
sufficiently.
A Return Thermostat operating an internal bypass
for condensation reduction.
An Over Temperature Thermostat (Overheat).
Burner Control with Lockout.
Internal Pump control with run on.
Pool Pump control with run on and out-of-season
exercise. (Requires external contactor)
Pool Temperature and Setting display. Engineer
selectable °C or °F.
User Indicators for Pool, Heating, Lockout, Over-
heat, and Service.
Engineer indicators of all switched outputs for
simple diagnosis.
Priority selection of Pool or Heating. Engineer
selectable.
Memory of: Filter, Overheat and Lockout occur-
rences.
Sensor failure detection and indication.
Control self checking with fault indication.
For more detail see the Commissioning (7:1) an
Fault Finding (10:1) sections.
Содержание COH110
Страница 60: ...14 Fig 4 9b Reillo bypass adjustment 9 04 02 Fig 4 9a Reillo bypass adjustment ...
Страница 63: ...17 9 04 02 ...
Страница 82: ...36 9 04 02 ...
Страница 83: ...37 Model 220 only Fig 8 3c Model 280 only Fig 8 3d Top Top Top 9 04 02 ...
Страница 86: ...40 9 3 BURNER PARTS 9 04 02 Model 110 443T58 ...
Страница 87: ...41 29 01 08 Model 180 459T55 3007708 ...
Страница 88: ...42 29 01 08 Model 220 464T55 3007708 ...
Страница 96: ...Station Lane Industrial Estate Witney Oxon Tel 01993 778855 Fax 01993 703407 Booklet 12 M3491 7 11 02 ...