1: USER INSTRUCTIONS
1:1 Important Safety Notes
To obtain the best possible performance and trouble
free operation from your Heater, it is important that
you read these instructions carefully. Your Pool
Heater has built-in safety features, which are detailed
in the relevant section of this manual.
Please note: It is essential in the interest of the Heater
efficiency and reliable performance that once the
Heater has been installed it is first commissioned by
an OFTEC.* registered engineer. It is the responsi-
bility of the installer to ensure that the Heater is com-
missioned.
If an engineer is not known, The Manufacturer will
be pleased to provide details of an approved
commissioning and servicing engineer from their list
of approved engineers.
If it is known or suspected that a fault exists on the
Heater, it MUST NOT be used until the fault has been
corrected by a competent engineer (see Section 1:13,
Trouble Shooting - Failure to Start)
It is essential that these instructions are strictly
followed for safe and economic operation. Failure to
observe these instructions may invalidate your right
to free breakdown cover during the guarantee pe-
riod.
As this an oil burner appliance some parts will be-
come very hot and so care must be taken.
We recommend that you keep these instructions in
a place near your Heater for easy reference.
1:2 Air Supply to Heater -
Conventional Flue
Where your Heater is used on an open conventional
flue system, a permanent air supply is required for
combustion. Clearances provided for air entry at the
rear of the appliance and into the building in which it
is installed, must be kept free of obstruction. For
further explanation please refer to section
5:1
and
5:2.
1:3 Connections
Your Heater should be connected to an electrical sup-
ply complying with the Electrical Wiring Regulations
(BS7671): as well as an oil supply complying with
BS541; and an appropriate flue system.
ALWAYS SWITCH OFF THE ELECTRICAL
SUPPLY before removing any of the covers for
cleaning.
If any part of the Heater or its flue is modified then
the guarantee will be invalidated.
1:4 Installation & Commissioning
After your Heater has been installed it MUST be
commissioned preferably by an OFTEC*. Regis-
tered installer, or by one of our recommended
service engineers. Commissioning involves testing
the Heater to ensure that it is working correctly,
and also setting the Burner correctly to ensure the
most efficient operation and use of fuel. If the
Heater has not been commissioned, it may not be
operating at the maximum efficiency possible, and
may also invalidate the guarantee.
*The Oil Firing Technical Association for the
Petroleum Industry 0845 6585080.
1:5 Quick Start
Check the Electricity and Oil supplies to the Heater
are on. If the Pool Pump is not controlled by the
Heater, turn it on. Turn on the Heater by turning the
Pool Temperature Control Knob clockwise to show
the required Pool temperature, the Heater will fire.
If the Heater fails to light see Section
1:13
, Trouble
Shooting - Failure to Start)
1:6 Summary of Controls
(left to right)
Boiler Pressure Gauge
Normal
- The needle should be in the area indi-
cated as * * NORMAL * * , if low, re-pressurise, see
Section 1:7
Pool Demand LED - GREEN
Off
- There is no Pool Heating Demand , pool
heating is off.
On
-There is a Pool Heating Demand the pool is
not yet up to temperature.
Flashing
- The Pool Heating Demand is Met , the
pool is up to temperature.
Pool Temperature Control
Knob
16°C to 41°C (60°F to 106°F)
Off
- There is no Pool Heating Demand , pool
heating is off.
Pump
- Runs Pool Pump only, if connected via
heater. ‘P’ is indicated on Pool Temperature Display.
- Pool +
- Setting for pool temperatures. Re-
quested temperature is displayed when setting,
actual Pool Temperature is displayed after 3 sec-
onds.
- Spa + -
Setting for Spa Temperatures. Required
temperature is displayed when setting, actual Spa
Temperature displayed after 3 seconds.
9-04-02
Содержание COH110
Страница 60: ...14 Fig 4 9b Reillo bypass adjustment 9 04 02 Fig 4 9a Reillo bypass adjustment ...
Страница 63: ...17 9 04 02 ...
Страница 82: ...36 9 04 02 ...
Страница 83: ...37 Model 220 only Fig 8 3c Model 280 only Fig 8 3d Top Top Top 9 04 02 ...
Страница 86: ...40 9 3 BURNER PARTS 9 04 02 Model 110 443T58 ...
Страница 87: ...41 29 01 08 Model 180 459T55 3007708 ...
Страница 88: ...42 29 01 08 Model 220 464T55 3007708 ...
Страница 96: ...Station Lane Industrial Estate Witney Oxon Tel 01993 778855 Fax 01993 703407 Booklet 12 M3491 7 11 02 ...