Installation Guide for FibeAir IP-20S, FibeAir IP-20S Assured
Page 87 of 105
Ceragon Proprietary and Confidential
6.5
1+1HSB/ 2+0 Single Polarization Remote Mount
Note:
This procedure can also be used for 1+0SP HW ready for 2+0SP
configuration.
HSB
ACCP
List of Items
Item Description
Quantity
Remarks
1
IP-20S RADIO
1
3
RFU-C POLE MOUNT KIT
1
4
RFU-C COUPLER/ SPLITTER KIT
1
For 1+1HSB configuration, a
coupler should be used
5
FLEXIBLE WG METRIC KIT
1
Required Tools
The following tools are required for the installation:
•
Metric offset hexagon key wrench #6
•
Phillips #2 screwdriver
•
Metric offset hexagon key wrench #2.5 and #3
Procedure
In 1+1 remote mount installation, the IP-20S radios are attached to a coupler,
while the coupler is connected to the antenna via flexible WG. To install the IP-20S
in a remote mount 1+1 configuration:
1 Mount the RFU-C coupler to the RFU-C pole mount bracket using the four M8
screws and washers supplied with the RFU-C Coupler kit, and tighten the
screws.