Installation Guide for FibeAir IP-20S, FibeAir IP-20S Assured
Page 83 of 105
Ceragon Proprietary and Confidential
6.4
1+1HSB/2+0 Single Polarization Direct Mount
Note:
This procedure can also be used for 1+0SP HW ready for 2+0 SP
configuration.
HSB
ACCP
List of Items
Item Description
Quantity
Remarks
1
IP-20S RADIO
1
2
RFU-C Coupler/Splitter KIT
1
For 1+1HSB configuration, a
coupler should be used
3
RFU-C TWIST KIT
1
Required Tools
The following tools are required for the installation:
•
Metric offset hexagon key wrench #6
•
Phillips #2 screwdriver
•
Metric offset hexagon key wrench #2.5 and #3
Procedure
In 1+1 direct mount installation, the IP-20S is attached to a coupler. To install an
IP-20S in a direct mount 1+1 configuration:
Notes:
For 15 and 18 GHz frequencies, two O-Rings are supplied in the Twist
kit and should be mounted in the twist grooves.
For 6 GHz frequency, a gasket is used instead of an O-Ring. The gasket
should be mounted between the twist and the RFU-C Coupler kit.
1 Mount the twist to the coupler using the O-Ring and four screws supplied in
the Twist kit, and tighten the screws.