3.5.6
Outdoor DC Cable Specifications
Table 4: Outdoor DC Cable Electrical Requirements
Cable type
2
tinned
copper wires
Wire gage
18 AWG (for <100m installations)
12 AWG (for >100m installations)
Stranding
stranded
Voltage rating
600V
Spark test
4KV
Dielectric strength
2KV AC min
Mechanical/ Environmental Requirements
Jacket
PVC, double, UV resistant
Outer diameter
7-10 mm
Operating & Storage temperature range
-40°C - 85°C
Flammability rating
According to UL-1581 VW1, IEC
60332-1
RoHS
According to Directive/2002/95/EC
Table 5: Outdoor DC Cable Mechanical/Environmental Requirements
Jacket
PVC, double, UV resistant
Outer diameter
7-10 mm
Operating & Storage temperature range
-40°C - 85°C
Flammability rating
According to UL-1581 VW1, IEC
60332-1
RoHS
According to Directive/2002/95/EC