Installation Guide for FibeAir IP-20S, FibeAir IP-20S Assured
Page 68 of 105
Ceragon Proprietary and Confidential
5.3.2
Remote Mount Installation with an Imperial Waveguide – 13
-
15 GHz
1 Mount the RFU-C Adaptor supplied with the RFU-C Remote Pole Mount kit
using the four flat screws supplied with the RFU-C Adaptor kit.
2 Mount the IP-20S using the four captive screws and washers supplied,
assembled, in the IP-20S.
3 Connect the Flexible Waveguide and sealing O-Ring supplied with the Flexible
Waveguide Imperial kit to the RFU-C Adaptor. Tighten the four screws
supplied with the Flexible Waveguide Imperial kit.