47
Technical instructions
Cm
-SOL
8.1.8. Pumps / Outputs
In this menu function of the output that is used must be defined (max. 8
outputs) and used output standby time can be defined after which
function of pump and valve protection is activated due to longterm
inactivity.
Installation, system components
8.1.8.1. Output functions
In this menu function of the output that is used must be defined (max. 8
standard outputs). 2 PWM and 2 analog outputs).
8.1.8.1.1. Output 1 function
In this menu function of the output that is used must be defined (one of
the 22 functions - pump of collector, tank, boiler, recirculation, pool,
mixing/reheating, electric heater, zone 2 way or zone 3 way valve).
Factory settings
Output 1 function
Output 2 function
Output 3 function
Output 4 function
Output 5 function
Output 6 function
Output 7 function
Output 8 function
Disabled
Disabled/Pump collector1/Pump collector2/
Pump tank1/Pump tank2/Pump tank3/
Pump tank4/Pump boiler1/Pump boiler2/
Electric heater/Recirculation pump/Pool pump/
Exchanger pump/Pump MRh/
3 way valve1/3 way valve2/3 way valve3/3 way valve4/
Valve1/Valve2/Valve3/Valve4
8.1.8.1.2. Output function 2
8.1.8.1.3. Output function 3
8.1.8.1.4. Output function 4
8.1.8.1.5. Output function 5
see 8.1.8.1.x. Output 1 function
8.1.8.1.6. Output function 6
8.1.8.1.7. Output function 7
8.1.8.1.8. Output function 8
47
selection
8.1.8.1.9./10. PWM 1/2 functio
In this menu functions of outputs for PWM pumps must be defined (one
of 6 functions - collector pumps, tank pumps to the collector.
NOTE:
Power to the pump is recommended to take from external power
supply, solar controller just controls the pump.
8.1.8.1.11./12. Analog Out 1/2
In this menu functions of outputs for analog steered pumps (0-10V) must
be defined.
NOTE:
Power to the pump is recommended to take from external power
supply, solar controller just controls the pump.
selection
Function PWM 1
Function PWM 2
Function output 1
Function output 2
Disabled
Disabled/Pump collector1/Pump collector2/
Pump tank1/Pump tank2/Pump tank3/
Pump tank4/
Factory settings