50
Technical instructions
Cm
-SOL
8.2.1.3.1. Pulse start collector 1
In this menu pulse start of collector can be enabled or disabled. All
preset times and also schedules are valid.
Pulse start coll.1
OFF
Factory settings
ON/OFF
Pump working time
10
Factory settings
min./max.
0 / 3600 sec
8.2.1.3.2.Pump work time
Setting of the pump working time in pulse start.
NOTE:
Working time must be adjusted according size and location of
collector field and collector sensor to have accurate reading from the
collector sensor to start heating the tank as soon as possible.
Pump pause time
15
Factory settings
min./max.
0 / 1440 min
8.2.1.3.3.Pump pause time
Setting of the pump pause time (not working) in pulse start.
NOTE:
Pause time must be adjusted according size and location of the
collector field and collector sensor to have accurate reading from the
collector sensor to start heating the tank as soon as possible.
8.2.1.3.4.Schedule
In this menu are additional menus for setting the schedule for working of
the pump in puls start (kick) for the collector field 1.
Schedule can be disabled or selected one of two tables with set time
intervals with enabled and disabled function of the pump.
8.2.1.3.4.1.Schedule
In this menu schedule can be enabled/disabled and one of the two
tables can be selected according to which puls start of the pump will
work.
NOTE:
If the puls start of the pump is enabled and Schedule is set to Off,
puls start of the pump will work all the time (24/7) according to the set
work/pause time. In this case puls start of the pump will work also during
the night and there is possibility to cool the tank trough the collector
down.
Factory settings
Schedule
Table 1
OFF/Table1/Table2
8.2.1.3.4.2.Table 1
In this menu it is possible to set 3 time intervals (3 start (green field) and 3
stop (red field) for each day in the week in which pump will work
according the set pulse start.
Factory setting: Impulse start of the pump is active from 08:00 to the
17:00 every day in the week. From 17:00 of the first day to 08:00 next
day puls start of the pump is not working.
Factory settings
Table 1
08:00-17:00 mon/tue/wed/thu/fri/sat/sun
Installation, collector
selection
selection
selection
unit.
unit.