28
Holiday option
OFF
ON/OFF
3.x. Holiday option
The holiday option includes system safety functions to postpone as long
as possible the appearance of steam in the solar collectors and to
prevent the pump and valves blockage due to very little or none water
consumption. By the actuation of the Holiday option the tank and
collector cooling function is activated aswell the pump/valve safety
function and frost protection of the water in the collectors. If it is not
wished to activate all before mentioned functions at once, the Holiday
option must be switched off and the individual wished safety functions
need to be activated manualy.
H
H
H
3.x.2. Duration
In this menu is defined how long from the moment of the Party function
actuation the DHW reheating will last according to the set temperature.
After the expiry of the selected time the Party function automatically
switches off.
Duration
1
selection
1 / 3 / 6 / 12 h
unit.
R
R
R
3.x.1. Recirculation
In this menu the recirculation function can be switched on or off.
All preset times aswell the schedule remain as adjusted.
Recirculation
OFF
ON/OFF
Pump working
5
min./max.
1 / 1440 min
jed.
3.x.2.Pump working time
Adjusting the pump working time when the recirculation is active.
NOTE:
The time must be adjusted to the recirculation system.
The recommendation is to set the recirculation pump work as
short as possible in order to cooldown the DHW tank as less as possible.
Pump pause time
15
min./max.
0 / 1440 min
jed.
3.x.3. Pump pause time
Adjusting the pump pause time when the recirculation is active.
NOTE:
Time must be adjusted to the recirculation system.
The recommendation is to set the recirculation pump pause as long
as possible in order to avoid to cooldown the DHW tank.
3.x. Recirculation
In this menu you can find the menus connected with the setting of the
DHW recirculation operation parameters.
In this menus you can set the time of work and pause of the recirculation
pump and define the time interval in which the operation and inactivity
time of the pump will be active.
NOTE:
It is necessary to switch it on in the installation menu.
Technical instructions
Cm
-SOL
User menu, operation
Factory settings
Factory settings
unit.
Factory settings
unit.
Factory settings
Factory settings